480W DIN rail with PFC fucnction power supply,Meanwell SDR-480P-48 Switching power supply/SMPS/PSU
Meanwell SDR-480P-48 Switching power supply
High efficiency 94% and low power dissipation
Cooling by free air convection
MODEL | SDR-480P-48 | |
OUTPUT | DCVOLTAGE | 48V |
RATEDCURRENT | 10A | |
CURRENTRANGE | 0~10A | |
RATEDPOWER | 480W | |
PEAK CURRENT | 15A | |
PEAK POWER Note.6 | 720W (3sec.) | |
RIPPLE & NOISE (max.) Note.2 | 120MVP-P | |
VOLTAGE ADJ. RANGE | 48~ 55V | |
VOLTAGE TOLERANCE Note.3 | ±1.2% | |
LINEREGULATION | ±0.5% | |
LOADREGULATION | ±1.0% | |
SETUP.RISEHOLD.TIME Note.5 | 1500ms, 150ms/230VAC 3000ms, 150ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 14ms/230VAC at full load | |
INPUT | VOLTAGERANGE | 90 ~ 264VAC 127~ 370VDC |
FREQUENCYRANGE | 47~63HZ | |
POWER FACTOR (Typ.) | 0.94/230VAC 0.99/115VAC at full load | |
EFFICIENCY (Typ.) | 94% | |
AC CURRENT (Typ.) | 5A/115VAC 2.5A/230VAC | |
INRUSH CURRENT (Typ.) | 40A/115VAC 80A/230VAC | |
LEAKAGE CURRENT | <0.8mA / 240VAC | |
PROTECTION | OVERLOAD | Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery |
>150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds | ||
OVER TEMPERATURE | 105± 5 (TSW : detect on heatsink of power switch) | |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||
OVER VOLTAGE | 56~ 65V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
FUNCTION | DC OK REALY CONTACT RATINGS (max.) | 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load |
ENVIRONMENT | WORKING TEMP | -25~+70 (refer to output load derating curve) |
WORKINGHUMIDITY | 20~95% RH non-condensing | |
STORAGE TEMP HUMIDITY | -40~+85 10~95%RH | |
TEMPCOEFFICIENT | ±0.03%(0~50) | |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |
SAFETY&EMC Note 4) | SAFETY STANDARDS | UL508, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 25 70%RH | |
EMI CONDUCTICN& RADIATION | Compliance to EN55011, EN55022(CISPR22)classB | |
HARMONICCURRENT | Compliance to EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, SEMI F47, GL approved | |
QTHERS | MTBF | 112.9Khrs min MIL-HDBK-217F(25) |
DIMENSION | 85.5*125.2*128.5mm (W*H*D) | |
PACKING | 1.6Kg; 8pcs/13.8Kg/0.9CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. 3 seconds peak power max. and the average output power should not exceed the rate power. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. |