Welcome to B2BAGE
Big Surprise Stanalone access controller from factory
Big Surprise Stanalone access controller from factory

Minimum Order: 0
Quality/Safety Certification: 0.00


Stanalone access controller
support 1000 users
build-in EM,Mifare one
proximity metal standalone

Stanalone access control system controller

 

 1.   Product Specification

Item 

specification

power

DC12V+10%; 1.2A

Lock Relay

12VDC/2A

Temperature

working:0°C~45°C

storage:-10°C~55°C

Relative Humidity

working:40%~90%RH

storage:20%~90%RH

User Capacity

1000

Frequency

125KHz or 13.56Mhz

Card Type

EM or Mifare compatible card

Read range

EM: 5-15cm;

Mifare: 3-5cm

External Reader

One extra W26 reader

Other Connections

Lock, exit button, bell, door sensor, alarm

 

 

3.   the LED and Buzzer

3.1Normal working status

3.1.1. Valid command: short beep      

3.1.2. In valid command: long beep

 

3.2Programming state

3.2...1Green LED on

3.2.2 Valid command: two short beeps

3.2.3 In valid command: Three beeps

4. Cancel Command

Press key # to cancel command before finish it

5.   Functions & Setup

5.1 Enter the programming mode

Press # + 6 digit code (default 881122)

 

5.2 Modify the programming code

Press 0+ input new 6-digit code +input again the new 6-digit code to confirm

 

5.3 Enroll/Add card

Press [5]

+ [3-digit user ID number] (2beeps)

+ [card 1] Beep, two beeps

+ [card 2] Beep, two beeps

+……

+ [card n] Beep, two beeps

+ [#] 2 beeps, finish enroll/add card

5.3 3-digit user ID number: Range from 001-999(card can be deleted by this code)

5.4 Delete valid Card

5.4.1 delete by ID number:

Press 7

+ 3-digit ID number (2 beeps)

+ 3-digit ID number (2 beeps)

+……

+ 3-digit ID number (2 beeps)

+ # (2 beeps), finish deleting process

5.4.2 Delete by presenting Card:

Press 7

+ presenting card1 (beep, 2beeps)

+ presenting card 2 (beep, 2beeps)

+……

+ presenting card n (beep, 2beeps)

+ # (2 beeps), finish deleting process

5.4.3 Delete all cards:

Please follow steps of return to the factory default.

5.5   Exit programming mode

Press # (2 beeps)

5.6   Open Door Mode

5.6.1          card or code/password mode

Press 1 + 0 (2 beeps)

5.6.2          card + personal code/password mode

Press 1 + 1 (2 beeps)

5.7   Code/password

5.7.1          code include personal code and public code

5.7.2          Disable changing personal code

Press 1 + 2 (2 beeps)

5.7.3          Enable Changing personal code

Press 1 + 3 (2 beeps)

5.7.4          Change Personal code (not under programming mode)

Press # for 5 seconds, show card(2 beeps), input 4 digit old code(2 beeps), input 4 new digit code, input again to confirm the new code (2 beeps)

5.7.5          Change public code

Press 3 + 4 digit code (defaulted 1234)

When the public code is 0000, the code is invalid in “card or pin” mode

5.8   Change Door Open Time

Press 2 + TT; TT stands for the delay time, such as door open time is 3 seconds, then TT=03

5.9 Anti-break alarm

5.9.1 closed anti-break alarm press [4] + [0]

5.9.2 Open anti-break alarm press [4] + [1]

5.10 Door contact sensor

5.10.1 Disabled door contact sensor: press [6] + [0].

5.10.2 Able door contact sensor: press [6] + [1]

5.11 Door sensor alarm

5.11.1 Disabled sensor alarm: press [8] + [0]

5.11.2 Able sensor alarm: press [8] + [1]

After turning on this function, the controller will give off continuous long beep when the door is not closed after normal opening, or the door is not opened through the controller.

5.12 Alarm delay time set

Press [82] + [TT].TT is time interval in second. For example, if the delay time is 3 seconds, then TT=03.

When the door is locked TT seconds, if the door contact sensor is in alarm status, the controller is in alarm mode. This function should be used when the door sensor alarm is on.

6 Restore factory default

Press [86] there will be 2beeps, 3 beeps and 3beeps after 5 seconds, then the factory defaults are restored.

7 User’s instruction

7.1 card or pin mode:

7.1.1 The pins should be entered in 2 seconds

7.1.2 Press # key to cancel password input

7.2 card + Private password mode

7.2.1(Reading card) (2 beeps) + (Personal password)

7.2.2 Press# key to cancel password input

8 Return to defaulted set See Wiring Diagram Notes

Short connect J2 in the PCB