Domnick Hunter dryer and filter
Compressed air filter
air compressor spare parts
compressor accessories

Domnick Hunter Dryer

HIROSS PoleStar Refrigerated Dryer

Problems Existing in Untreated Compressed Air:

Compressed air is an important power which is widely used in various area of industry. All air of compressed system is from atmosphere, among which has large amount of dust, vapor, not fully burned hydrocarbon and bacteria.
In addition, lubricant system of air compressor will also produce some pollutants. All of this mixed together will form a kind of corrosive oil sludge which damages device, corrodes pipeline, increases maintenance cost, pollutes environment, etc.

Solutions:
Installation of one set of Domnick Hunter Oil-Xplus filter and PoloStar Refrigerated dryer system can avoid huge economic loss caused by above problems.


Characteristics of PoloStar Refrigerated Dryer:

Precise Control
microprocessor control panel (PD1100 and above models are standard configuration), use conveniently, precision control and easy maintenance.

Simple Installation
PoloStar PD series Refrigerated dryer is the most compact one in similar products, its positioning and installing are very convenient. PD0050-PD0300 model of dryer even can install on the wall.

Easy to Use
PoloStar PD dryer can operate in extremely bad condition; it can work normally under max. air inlet temperature of 60 and max. ambient temperature of 50.

High Reliability
PoloStar PD series Refrigerated dryer can ensure continuously normal operation. Firmly aluminum heat exchanger advanced scroll compressor, PD2600 and above configuration of condenser and filter all have high reliability, which improve performance of dryer and reduce possibility of maintenance.

Drypack High Efficiency Heat Exchanger
PoloStar PD series Refrigerated dryer adopts advanced Drypack heat exchanger (PD0700 and above model are standard configuration).

Technical Parameter and Model :

ModelFlowInput PowerInterface SizeWidth AHeight BDepth CWeightRecommended Filter Model
Nm3/minkWmmmmmmkgPrefilterPostfilter
PD00500.50.223/8"BSP19745545020AO-0017G-CAA-0017G-C
PD010010.391/2"BSP28253060033AO-0017G-CAA-0017G-C
PD020020.753/4"BSP35260570055AO-0058G-CAA-0058G-C
PD030031.053/4"BSP35260570058AO-0058G-CAA-0058G-C
PD070071.171½"BSP61579155270AO-0145G-CAA-0145G-C
PD1100111.542"BSP9201015672140AO-0220G-CAA-0220G-C
PD1400141.912"BSP9201015672144AO-0330G-CAA-0330G-C
PD1900191.962"BSP9201015672150AO-0330G-CAA-0330G-C
PD2600263.47DN80101015001310420AO-0430G-CAA-4330G-C
PD3500354.23DN80101015001310450AO-0620G-CAA-620G-C
PD4400445.68DN100101015001310470AO-1000F-CAA-1000F-C
PD6000607.42DN100101015001810550AO-1000F-CAA-1000F-C
PD73007311.0DN150101015001810580AO-1300F-CAA-1300F-C


Correction Coefficient in Different Working Condition:

AWorking Pressurebarg3456789101112
Correction Coefficient0.690.790.880.9511.051.091.121.151.18
BAir Inlet Temperature 3035404245505560
Correction Coefficient1.481.291.0810.900.750.630.52
CAmbient Temperature 2025303538404550
Correction Coefficient1.161.121.081.0310.980.800.52

Air flow in different working condition can be got by multiplication of nominal capacity and correction coefficient in above table.
(for example, actual dryer capacity=nominal capacity × factor A × factor B × factor C)

Max. Working PressurePD0050-PD030016barg
PD0700-PD730012barg
Max. Air inlet Temperature60
Max. Ambient Temperature50
Power SupplyPD0050-PD0700230V/1Ph/50HZ
 PD1100-PD7300400V/3Ph/50HZ
Cooling Methodstandardwind cooled; for PD4400-7300, water cooled is available
RefrigerantPD0050-PD0300R134a
PD0700-PD7300R22




AO grade filter
high efficiency filtration
filtrate dust particle, water and oil mist which are larger than 1 micron, max. oil mist content is 0.5mg/m3@21

AA grade filter
high efficiency and precision filtration
filtrate dust particle, water and oil mist which are larger than 0.01 micron, max. oil mist content is 0.01mg/m3@21

ACS grade filter
activated adsorption and filtration
remnants of oil steam are not surpassed 0.003mg/m3@21.