1. BUS Type or Sub-Linear Type or Tray-Mounted
2. Must Work with our CA-217A-B Probe
CA-2100C Combustible Gas Alarm Controller
Working Method | Auto Patrol | Output Power | DC12V500mA (Supply Power to Detector) |
Communication | 4~20mA Standard Signal | Working Power | AC220V/50Hz |
Transmission Distance | ≤ 1000 m | Alarming Function | Two Level Alarm, Alarm Point can be set up |
Sampling Rate | <4 road/second | Alarming Sound |
|
System Capacity | 2 Line | Display Method | Digital Tube Rotational Display |
Display Error | +- 5% | Working Environment: | Tem -100C~+500C Hum 300C~+950C |
Weight | About 1.5 Kg | Dimension | 260X80X160 mm |
|
| Product Performance Standards: | GB16808-1997 GB16808-2008 |
CA-2100A Combustible Gas Controller
Working Method | Auto Patrol | Output Voltage: | DC24V@500mA (Supply Power to The Probe #CA-217A-B) |
Communication Interface: | 4-20mA Standard Signal | Working Voltage: | AC220V/50Hz |
Transmission Distance: | ≤ 1000 m | Alarming Function: | 2 Level Output |
Sample Rate: | <4 Channels/Second | Max. Capacity of System: | 2 Channels |
Display Method: | Digital Tube Display rotationally | Display Error: | <+-5% |
Working Environment: | Tem-10%~+50% RH 30%-95% | Display Function: | LED Display |
Weight | About 2.5 Kg | Controller Size: | 290mm*210mm*85mm
|
Connection Thread : | 1/2G Inner Thread | Performance Standards:
| GB16808-1997/ GB16808-2008 |
CA-2100D Combustible Gas Controller
Working Method | Automatic Patrol | Output Voltage: | DC24V@1A (Supply Power to The Probe #CA-217A-B) |
Communication Interface: | RS485 | Working Voltage: | AC220V/50Hz |
Transmission Distance: | <1000 m | Alarming Function: | 2 Level Output |
Sample Rate: | <4 Channels/Second | Max. Capacity of System: | 4 Channels |
Display Method: | Four-passage Concentration Real-time Dislay | Display Error: | <+-5% |
Working Environment: | Tem-10%~+50% RH 30%-95% | Weight: | About 3kg
|
Controller Size: | 350mm(Length)*230mm(Width)*80(Thickness)mm | Performance Standards: | GB16808-1997 GB16808-2008 |
CA-2100E Combustible Gas Controller
Working Method: | Automatic Patrol | Output Voltage: | DC24V@3A (Supply Power to The Probe #CA-217A-B) |
Communication Interface: | RS485 | Working Voltage: | AC220V/50Hz |
Transmission Distance: | <1000 m | Alarming Function: | 2 Level Output |
Sample Rate: | <8 Channels/Second | Max.Capacity of System: | 16 Channels
|
Display Method: | Concentration Display, SpecificPassage Display Alarming Passage Takes Priority | Display Error: | <+-5% |
Working Environment: | Tem-10%~+50% RH 30%-95% | Display Function: | LED Display |
Weight: | About 3kg | Controller Size: | 350mm(Length)*230mm(Width)*80(Thickness)mm |
Performance Standards: | GB16808-1997/ GB16808-2008 |
|
|