0.6/1kv all aluminium conductor
superior quality with competitive price
trustworthy
fast develivery
Detailed Product Description
1.bare conductors AAC, ACSR, AAAC
2.AAC Bare Conductors 99.8% Purity ASTM, BS B232,DIN48201 and others
3. 12-17 days delive
AAC Bare Conductors 99.8% Purity ASTM, BS
AAC Cable is used in power transmission and distribution lines.
2 IEC61089, BS215 part1, DIN48201 part5, ASTM B232,DIN48201.
2.AAC Standard:ASTM B 231,BS 215-1,DIN48201,IEC 61089
AAC Bare Conductors 99.8% Purity ASTM, BS
3.Application:
AAC cable is used in ovedhead electric power transmission and distribution lines with various grade voltages.
4.Packing: Strong Wooden Reel
British Sizes-BS215-1
Code Name | Nominal Aluminium Area | Stranding And wire diameter | Sectional Area | Approximate Overall diameter | Linear Mass | Calculate D.C Resistance At20 | Calculate Breaking Load | Final Modulus of Elasticity | Corefficient Of linear expansion
|
Mm² | mm | Mm² | mm | Kg/km | Ohm/km | daN | hbar | / | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 1.227 | 399 | 5900 | 23x106 |
Aphis | 25 | 7/3.35 | 26.40 | 7.2 | 73 | 1.081 | 411 | 5900 | 23x106 |
Gnat | 25 | 7/2.21 | 26.8 | 6.6 | 73 | 1.066 | 459 | 5900 | 23x106 |
AAC Bare Conductors 99.8% Purity ASTM, BS
German Sizes-DIN48201
Area | Stranding and Wire diameter | Overall diameter | Linear mass | Calculated Breaking load | Calculated D.C Resistance at 20 | |
Nominal(mm²) | Actual(mm²) | mm | mm | Kg/km | daN | Ohm/km |
16 | 15.89 | 7/1.71 | 5.1 | 44 | 290 | 1.8018 |
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 |
35 | 34.36 | 7/2.50 | 7.5 | 94 | 585 | 0.8332 |
50 | 49.48 | 7/3.00 | 9.0 | 135 | 810 | 0.5786 |
50 | 48.36 | 19/1.80 | 9.0 | 133 | 860 | 0.5950 |
70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 |
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3048 |
120 | 117.00 | 19/2.80 | 14.0 | 322 | 1910 | 0.2459 |
USA Sizes-ASTM B 231
Code name | Total Area | Stranding and Wire diameter | Approximate Overall diameter | Linear Mass | Nominal Breaking load | Maximum Resistance At 20 | |
AWG or MCM | mm² | mm | mm | Kg/km | daN | Ohm/km | |
Peachebell | 6 | 13.29 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 |
Rose | 4 | 21.16 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 |
Iris | 2 | 33.61 | 7/2.474 | 7.42 | 93 | 597 | 0.8577 |
Pansy | 1 | 42.39 | 7/2.776 | 8.33 | 117 | 732 | 0.6801 |
Poppy | 1/0 | 53.48 | 7/3.119 | 9.36 | 147 | 873 | 0.5390 |
Aster | 2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 1100 | 0.4276 |
Phlox | 3/0 | 85.03 | 7/3.932 | 11.80 | 234 | 1347 | 0.3390 |
Oxlip | 4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 1698 | 0.2688 |