Item/parameter/ modelSC0.35-0.4-95/70-AIISC1.4-0.7-95/70-AIISC2.87-0.7-95/70-AIISC0.7-0.7-95/70-AII
Rated evaporation capacityMW0.351.42.80.7
Operation pressureMpa0.40.70.70.7
Steam temperature°C95959595
Water-inlet temperature°C70707070
Boiler heating efficiency%72.2378.8479.1877.4
Area of Boiler Heating surface m219.165.9112.229.05
Area of stokermm0.8923.24.552
Heating areamm300012000240006000
FuelCoal available  Coal II,low heat capability 17000-21000KJ/KG
Consumption kg/h960290580145
Inlet pipe diameterMMPn1.6 Dn80Pn1.6 Dn125Pn1.6 Dn125Pn1.6 Dn125
Dimensions of biggest parts for shipment (L x W x H)m2.9X2.0X2.86.28X2.56X3.337.36X2.6X3.545.99X1.85X3.2
Weight of biggest parts for shipmentt4.617.52616.3
Overall dimensions of boiler assembled  (L x W x H)m3.4X2.5X3.37.5X4.26X4.658.3X4.3X4.645.99X2.1X3.88
Total weightt4.721.33119.8
Water supply pumpModel IS50-32-160IS80-50-160IS100-80-160IS65-50-160
flowm3/h155010030
Pump head m29.6323230
 Motor powerkw1537.53
Induced draft fanModel Y6-41-13 N3.55CY6-41-13 NO5.4CY6-41-13 NO7.1CY6-41-13 NOO4.5C
Ventilationm3/h3162-8974350-89018170-158192574-5522
Wind pressurePa1651-6713240-25683283-24542873-2058
Motor PowerKW2.211225.5
BlowerModel  G6-41-13 No5.4aG6-41-13 No6.4aG6-41-13 No3.3a
Ventilationm3/h 2130-43583596-73581090-2301
Wind pressurePa 1254-99418111-1436954-1936
Motor Powerkw 35.51.1