VS-AH air heater cleaner is mainly used to clean heat exchange surface of rotary air heater.
VS-AH air heater cleaner is mainly used to clean heat exchange surface of rotary air heater. The speciality is below:
1. Reaonable arrangement of nozzle and nozzle body drive speed will make sure the efficient blowing of heat exchange surface.
2. The change of control disc place will change the blowing pressure
3. Unique soft valve base design sill not affect the sealing impact with the change of temperature
4. Box beam instructure provide support and maximum protect for all parts and accessories
5. The efficient protect from beam to elastic cable will improve elastic cable’s longevity
6. Lance flanged design is welding type flange, flange is connected with lance arc, small stree, long life.
Blowing travel ength | According to the contract requirement |
Lance move speed | ~86mm/min |
Medium | Steam or compressed air |
Pressure | ~1.5Mpa |
Efficient blowing radius | ~2m |
Nozzle number&bore | It depends on air heater general drawing |
Motor type, power | 0.18KW/3P/50Hz |
Weight(about) | 360kg+115kg per meter travel (exclude the furance parts of lance tube) |
Motor | 0.18KW/3P/50Hz |