CK200204 dual-compressor bus ac controller
Minimum Order: 0
Quality/Safety Certification: 0.00
CK200204 bus air condition controller
1.Dual-compressor bus
2.Fully-automatic control;cooling
2.WINIA MANDO, DAIH
CK200204 bus exclusive air condition controller apply to the climate control of dual-compressor bus.
Function: fully-automatic control, cooling, fresh air, memory, error alarm, shift function, input voltage detecting.
The second function:
1)Defrost temp. display (press fresh air button no less than 3S)
2))Hold cool (press cool button no less than 3S)
Application case: WINIA MANDO, DAIHAN, DENSO, YUTONG Bus, ZHENGTONG Bus, KINGLONG Bus.
Technical data:
Technical date | CK200204 |
Power supply | 24V(DC20V-DC32V) |
Power consumption | 4.5W |
Current | Max.200mA |
Dimensions | 168X66X54 |
Display | LED (true color/red) |
Ambient temperature | -30°c—80°c 5%-95%RH Non-condensing |
Storage temperature | -10°c—70°c 5%-95%RH Non-condensing |
Display precision | Dual digit display of set temp., accuracy 1°c; dual digit display of inside temp. accuracy 1°c |
Humidity test standard | Temp. control based on the temp. of return air inlet, the defrost sensor controls defrost temp., defrost on at 2°c, defrost off at 7°c |
Connector | Plug DJ7171-3-21 |
Faceplate level | IP54 |
EMC level | EN50081&EN50082-2 |
Security level | Applied to EN61010-II, Pollution degree: II |
Weight | 335g |
Input | 1) Inside temp. sensor(25°c, Rb=5K,B=3274) |
2) Defrost sensor 1,2(25°c, Rb=5K,B=3274) | |
3) Pressure switch 1,2 | |
4) Power(generator) | |
5) ACC(battery) | |
6) Backup lamp power | |
Output | 1) Condenser fan(max.1A) |
2) Fan high (max.1A) | |
3) Fan mid (max.1A) | |
4) Fan low (max.1A) | |
5) Fresh air open (max.1A) | |
6) Fresh air close (max.1A) | |
7) Compressor clutch 1(max.1A) | |
8) Compressor clutch 2(max.1A) |
Our Principle:
Professional - Focus - Attention
Our Cooperation Partners: