UPS battery charger
1.20/40A charging current
2.can be paralleled
3.overvoltage,undervoltage protection
4.various battery
12V/24V Supre UPS Battery Charger
1. General Description
Responding to the demand of the large charging ability to diverse types of batteries in the market. Battery Charger adopts the reliable high frequency structure, compatible with wider range of input voltage from 90Vac to 280Vac, and owns the 12Vdc or 24Vdc output selections. It provides the maximized flexibility in terms of wider input voltage, selectable output voltage, customized output current, and selective charging modes of diverse types of batteries that maximized the battery lifetime. The Battery Charger is desirable for satisfying your various demands of the large power charging ability and is the best choice for the multiple power surroundings.
2. Features
three stages variable charging voltage algorithm by timing for maximizing the battery life;large charging capacity design (40 Amp for 12Vdc mode; 20 Amp for 24Vdc mode) for shortening the charging time;selectable charging currents base on connected battery capacity for extending the battery life time with suitable charging current;multiple voltages charging design for protecting diverse types of batteries of Flooded Lead-Acid, Gel and AGM chemistries batteries;wider input voltage range from 90Vac to 280Vac for universal input;high AC to DC converting efficiency design (higher than 80%);smart fan control for maximizing the performance and fan lifetime.3.Technical specifications
input | |
input voltage | 180-280 Vac full performance |
90-180 Vac automatically derate to 50% of full load current | |
frequency | 40 Hz to 70 Hz |
Nominal input current at rated output | less than 9 Aac |
Voltage Measurement Accuracy | +/- 8 Vac |
Frequency Measurement Accuracy | +/- 1 Hz |
output | |
nominal voltage | 12/24Vdc manual adjustable |
output current | input voltage 180-280V, output current 40 Amp for 12 V mode output current 20 Amp for 24 V mode |
input voltage 90-180V, output current 20 Amp for 12V mode output current 40 Amp for 24V mode | |
raged output current | manual adjustable |
current accuracy | +/- 6% of full rated output current @25°C, for target currents across the range from 10% rated output (for absorption exit criteria accuracy) to the current limit setpoint. |
load regulation | 1.50% |
current limit | 40-44 Amp |
Dead battery charging | 8-14.9 Vdc at 100% of rated output current |
8-29.8 Vdc at 100% of rated output current | |
selectable battery type | flooded lead acid, Gel AGM, manual adjustable |
Parallel outputs | Maximun two charger units connection in parallel |
efficiency | over 80% |
Protection | |
input overvoltage | Unit must be safe for input voltage up to 300 Vac RMS (and up to 430 V peak), need not be operating. Above this level the unit may be damaged. |
reverse battery polarity protection | Non-destructive reverse battery polarity protection with fuses. Unit shall not sustain damage and shall meet all specifications after fuse replacement. |
input undervoltage | Unit must not be damaged for all input voltages from 0-300Vac. Shutdown or input current limit or other means may be applied when input voltage is out of normal operating range. |
output overvoltage 12/24 mode | Unit will shut down if charging voltage is more than target charging voltage + 1 Vdc for more than 2 seconds; unit will restart when voltage leass than target charging voltage for more than 2 seconds. For battery OVP the unit will restart in the same stage. |
Unit will shut down if charging voltage is over than target charging voltage + 1.5 Vdc for more than 2 seconds; unit will restart when voltage is less than target charging voltage for more than 2 seconds. For battery OVP the unit will restart in the same stage. | |
charger overtemperature protection | The internal temperature of the charger will be meassured by NTC. Based on these meassurements, unit will shut down if the temperature exceeds 60°C. Unit will restart when environment temperature cools to 55°C. |
Environmental | |
operation temperature | nominal ambient temperature: 25°C operating ambient temperature range: -10°C to 60°C full performance:-10°C to 40°C derate mode: +40 °Cto 60 °C automatically shut down when over 60 °C. |
relative humidity | 5-95% without condensation |
noise | unit requirements: below 50dB (A) meassured at 1 meter distance with fan full working. |
storage conditions temperature | at -20°C to 80°C |
cooling | fan cooling with smart fan control |
Mechannical | |
Dimension (D*W*H) mm | 224*255*80 |
unit weight | 1.7 kg |