according to IEC60898-2 and GB10963.2 standards,used in circuit breaker with voltage of 250V,500V,750V,1000V and rated current


1. Application

The DC mini circuit breaker are produced according to IEC60898-2 and GB10963.2 standards,used in circuit breaker with voltage of 250V,500V,750V,1000V and rated current of 1~100A for overload and short-circuit protection, common used at DC power,electric locomotive,metro,ship and power supply.

2. Specification

The circuit breaker have performance of small volome,high breaking capacity,short arcing distance,fast close and convenient installation.

Special permanent magnetic field arc blow technology can ensure the reliability and stability of DC arc breaking.

Special designed arc leading part can lead the arc to arc chamber and help the permanent magnetic lead the arc to arc fence fastly.

The circuit breaker can used with various kinds of accessories (OF,SD,MX+OF,MN etc.)

The circuit breaker can assembled to multi poles (2,3,4 poles) according to different voltage and breaking capacity to satisfy customer’s requirement.

The circuit breark can be special designed according to customer’s special requirement.

3. Technical data

Pole

1P

2P

3P

4P

Rated voltage Ue

250V DC

500V DC

750V DC

1000V DC

Rated current In

B curve:6A,10A,16A,20A,25A,32A,
40A,50A,63A,80A,100A

C curve:1A,2A,3A,4A,6A,10A,16A,20A,25A,
32A,40A,50A,63A,80A,100A

Rated short circuit breaking capacty Icn(T=4ms)

1P(125V):10kA,2P(250V:10kA,3P,4P(440V):6kA

Instantaneous tripping type

B curve(4~7In),C curve(7~15In)

Delay tripping time

cold state 1.13In
(In≤63A t≥1h non tripping;In>63A t≥2h non tripping);

hot state 1.45In
(In≤63A t<1htripping; In>63A t<2h tripping);

Rated withstanding voltage Uimp

4kV

Mechinal life

10000 times

Enviorment

Ambient temperature:-5°C~+40°C

Applicable auxiliary parts

OF auxiliary contact,SD alarming contact,
MX+OF shunt release,MN under voltage release

Max wiring capacity

25mm2~50mm2

Standards

IEC60898-2 GB10963.2

4. Wiring diagram


5. Wiring conduct area parameter

Rated current(A)

Conduct area

6A and below

1mm2

10A

1.5 mm2

16A,20A

2.5 mm2

25A

4 mm2

32A

6 mm2

40A,50A

10 mm2

63A

16 mm2

80A

25 mm2

100A

35 mm2

6. Figure and installation dimension.



9. Din rail dimension.

 