VS1 12kv circuit breaker
VS1 12kv circuit breaker

Minimum Order: 0
Quality/Safety Certification: 0.00


ZN63(VS1)-12 Side Installation Type Indoor High Voltage Vacuum Circuit Breaker
Rated Voltage: 12kV & Frequency 50Hz 3 phase

ZN63(VS1)-12 type Side installation indoor high voltage vacuum circuit breaker is Indoor high voltage switchgear, Applies to rated voltage 12kv, frequency 50Hz three-phase power system,Electrical protection and control as the use of vacuum circuit breaker as a result of the special advantages, in particular the need for frequent operation under the rated current or short-circuit current breaking many places.

 

ZN63(VS1)-12 type Side installation indoor high voltage vacuum circuit breaker using fixed installation, the main switchboard for the fixed, the circuit breaker can be used alone, but also for the ring network power supply, box-type variable, or a variety of non-standard power supply system.

 

The use of environmental conditions:

1.Ambient temperature: not higher than +40 °C, not less than -15°C(at -30 °C to allow storage and transportation).

2. Altitude: not exceed 1000m.

3. Relative humidity: daily average of not more than 90%, month average of not more than 90%.

saturated vapor pressure daily average of not more than 2.2 × 10-3MPa, month average not more than 1.8 × 10-3MPa.

4. Earthquake intensity: not more than eight.

5. No fire, explosion hazard, serious filthy, chemical corrosion, as well as places of intense vibration.

 

Mainly technical parameters

 

NO

Item

Units

parameters

1

Rated voltage

KV

12

2

Rated insulation level

Rated Lightning Impulse voltage tolerance

KV

75

1min Frequency voltage

42

3

Rated short-circuit breaking current

KA

20/25

31.5

4

Rated current

A

630

1250

630

1600

2500

5

Rated thermal stability of current (RMS)

KA

20/25

31.5

 

6

Dynamic Stability rated current (peak)

63

80

 

7

Rated short-circuit closing current (peak)

63

80

 

8

Rated short-circuit breaking current breaking number

times

50

9

Frequency tolerance of the secondary circuit voltage (1min)

V

2000

10

Rated operating sequence

 

0-0.3s-CO-180s-CO

11

Rated thermal stabilization time

S

4

12

Rated a single / back-to-back electric current breaking device group

 

630/400

13

Mechanical life

Times

10000