Harmonic Power Clamp Meter
Measuring power, voltage, current, peak value, phase, frequency, power factor, phase angle
MS2208
Harmonic Power Clamp Meter
• Measuring power, voltage, current, peak value, phase, frequency, power factor, phase angle, and reaction factor, etc. of single-/three-phase circuit; automatic phase sequence testing is possible for 3-phase measurement.
• True effective value measurement: accurate measurement is possible even with serious distortion in current waveform.
• Low-consumption high-speed single-chip microprocessor is employed and sophisticated algorithm is applied, as a result, results can be obtained rapidly and precisely, and up to 20 harmonics and distortion value thereof can be measured.
• Current clamp size: 26mm
• Conform to the IEC61010-1 Standard CAT.III 600V
• Power supply: 1.5V AAA Battery X 3
• Dimensions: 208mm X 78mm X 35mm
• Weight: about 350g (with battery)
• AC Voltage(TRMS): 10V ~ 600V ± (1.0% + 5)
• AC Current(TRMS): 2mA~3999mA ± (2% + 5)
4A~200A ± (2% + 5)
• Single-phase active power: 0.1W~120KW ± (3% + 5)
• Power factor: 0.3~1 Capacitive ± (0.02 + 2)
0.3~1 Inductive ± (0.02 + 2)
• Passive power: 0.1W ~ 120KW ± (3% + 5)
• Frequency: 30Hz~1kHz ± (0.5% + 1)
• Harmonic test
Harmonic Number 1 ± (3.0% + 10dgt)
Harmonic Number 2-6 ± (3.5% + 10dgt)
Harmonic Number 7-8 ± (4.5% + 10dgt)
Harmonic Number 9-10 ± (5.0% + 10dgt)
Harmonic Number 11-15 ± (7% + 10dgt)
Harmonic Number 16-20 ± (10% + 10dgt)