1. flow rate: 1 CFM
2. UCL calculation
3. Build-in thermal printer
4. 1000 samples data storage
Major technical indicators (JJG54F88 implementation of the dust particles technical verification regulation)
1.Self-purification time: ≤ 20min
2.The relative deviation of repeatability: <20%
3.The accuracy of the relative size deviation: <40%
4.The relative size dispersion of error: <30%
5.Flow rate: 28.3L/min (ICFM)
6.Security: insulation resistance> 50MΩ (normal atmospheric conditions)
Main technical parameters
1.The effective power of semiconductor laser: 120mW
2.Laser wavelength: 780nm
3.Photosensitive tube response: 880nm
4.Power supply: 220VAC ± 10% 50Hz
5.Maximum allowable sampling concentration:35000 per square meters (Dust particle size can not be more than 0.5μm), sampling air can not contain acid, alkali and other corrosive gas.
6.6 size channels: 0.3,0.5,1,3,5,10 (μm)
7.Sampling period: 6-96SEC optional
8.Sampling points: 2 to 9 optional
9.The number of sampling points: 3
10.Sample volume: 2.83L(0.1CFM) to 45L optional
11.Size: 350*320*126(width * deep * High)
12.Weight: 6kg
The use of environmental conditions
1.The temperature of 5 °C ~ 35 °C
2.Relative humidity RH ≤ 75% RH
3.Atmospheric pressure: 86kPa-106kPa
3. Working parameter set :
T:10 L:01 C:00 UCL:OFF BL:OFF 0.3μm 038613 0.5μm 011209 1.0μm 002207 3.0μm 000557 5.0μm 000039 10μm 000002
Rec:OFF prt:ON Flow:1CFM |
Page:007 10/07/08 15/20/18 T:10 L:01
0.3μm 7528613/m3 0.5μm 3917209/m3 1.0μm 872807/m3 3.0μm 260887/m3 5.0μm 28439/m3 10μm 763/m3
Rec:OFF prt:ON Flow:1CFM |