Welcome to B2BAGE
pH/mv/Ion Concentration/Conductivity/Dissolved Oxygen Meter
pH/mv/Ion Concentration/Conductivity/Dissolved Oxygen Meter

Minimum Order: 0
Quality/Safety Certification: 0.00


Measuring Parameters: pH, mV, ion concentration, conductivity, resistivity, TDS, salinity, Dissolved Oxygen and Temperature

Measuring Parameters: 

pH, mV, ion concentration, conductivity, resistivity, TDS, salinity, Dissolved Oxygen and Temperature

 

Features and Applications: 

1. Multi-parameter meter contains more than ten kinds of measuring parameters, is suitable for high accuracy measurement, and excellent product for both good performance and low cost.

2. DO measuring mode has automatic compensation for temperature, salinity and air pressure.

3. pH measure mode for high purified water and ammonia added purified water can be setup, suitable for use in electric power and petrifaction industry.

4. Inside setup with function of high purified water non-linearity automatic temperature compensation, suitable for accurate conductivity measurement for high purified water.

5. There are four kinds of ion concentration measuring units: pX, mol/L, mg/L and ppm.

6. Equips model 2503 pH electrode, suitable for measure the weaker ionic strength, feculent and colloidal solution

 

Technical Parameters:

pH:

Measuring range

(-1.999 to 19.999) pH

Resolution

0.1/0.01/0.001 pH

Accuracy

Meter:±0.002 pH, connect meter with electrode:±0.01pH

Input current

≤1×10-12 A

Input impendance

≥3×1012 Ω

Stability

±0.002 pH/3h

(0 to 100) °C(automatic or manual)

 

mV:

Measuring range (mV/ORP/EH)

-1999.9 mV to 0 to 1999.9mV

Resolution

0.1mV

Accuracy

±0.03% FS

 

Ion Concentration:

Measuring range

0.00 to 14.00pX

Display unit

pX, mol/L, mg/L, ppm

Accuracy

Meter:±0.5 % reading(monovalent), ±1.0 % reading (bivalent)

Temp. compensation range

0 to 60 °C(automatic or manual)

 

Conductivity:

Measuring range

Conductivity:

(0.00 to 20.00)μS/cm  (20.0 to 200.0)μS/cm

(200 to 2000)μS/cm   (2.00 to 20.00) mS/cm

(20.0 to 200.0) mS/cm  (200 to 2000) mS/cm(K=10)

Resistivity:(0 to 100) MΩ·cm

TDS:     (0 to 100) g/L

Salinity :  (0 to 100) ppt

Resolution

0.01/0.1/1μS/cm  0.01/0.1/1 mS/cm

Accuracy

Meter:±0.5% FS,connect meter with electrode:±0.80% FS

Temp. compensation range

(0 to 50) °C(automatic)

Electrode constant

0.1 / 0.5 / 1 / 5 / 10 / 50 /100 cm-1

Reference temperature

25°C, 20°Cand 18°C

 

Dissolved Oxygen:

Measuring range

(0 to 40.00) mg/L(ppm)  (0 to 200.0) %

Resolution

0.1/0.01 mg/L(ppm)  1/0.1%

Accuracy

Meter:±0.10 mg/L, connect meter with electrode:±0.40 mg/L

Response time

≤30 s (25°C, 90% response)

Residual current

≤0.1 mg/L

Temp. compensation range

(0 to 45) °C(automatic)

Salinity compensation range

(0 to 45) ppt(automatic)

Air pressure compensation range

(80 to 105) kPa(automatic)

Automatic calibration

Air saturated by water; water saturated by air

Electrode type

Polarogram type

 

Temperature:

Measuring range

-10°Cto 110°C

Resolution

0.1°C

Accuracy

5 to 60°C range: ±0.4°C  other range: ±0.8°C

 

Other Technical Parameters:

Data storage

300 groups

Storage content

Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time

Power

DC9V/300mA

Communication connector

RS-232

Size and weight

160 x 190 x 70mm/880g

Quality and safety certification

ISO9001:2000, CE and CMC

 

Working Condition:

Environment temperature

5 to 35 °C(0.01 grade) 15 to 30 °C(0.001 grade)

Environmental humidity

≤75%

IP rating

IP54  Dustproof and waterproof