12.1'''Inch Color TFT Display Multi-parameter Patient Monitor +ETCO2 New brand!!!
12.1'''Inch Color TFT Display Multi-parameter Patient Monitor +ETCO2 New brand!!!

Minimum Order: 0
Quality/Safety Certification: 0.00


12.1" color TFT LCD screen with maximum 7-waveform display. Adjusting of lightness continuously make patient more comfotable.

Patient monitor:

Model:LDM-G3E

Description:

12.1-inch display 6-parameter Patient Monitor With Printer and ET-CO2+Dual Temp

Model:LDM-G3E

Description:

12.1-inch display 6-parameter Patient Monitor With Printer and ET-CO2+Dual Temp

 

Function:

 

Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR. 
12.1" large-screen color TFT display
Built-in high-capacity battery, up to 4 hours working time
7-lead ECG waveforms display ,big fonts observational interface
Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
Arrhythmia and S-T segment analysis and pacemaker detection
Protection against interference from defibrillation and electrosurgical Unit
Applicable for ICU, CCU, operation, adult, pediatrics and neonatal patient
ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery  


Standard Configuration:
 NIBP, SPO2, ECG, PR, RESP, 2-TEMP,  Built-in printer, Capnograph/ ETCO2    Optional:
Single/Dual IBP(Invasive blood pressure)

 

Specification:

ECG

Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads ( R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV,  auto

HR and Alarm

Range
          Adult: 15 ~ 300 bpm
          Neo/Ped: 15 ~ 350 bpm
Accuracy : +/- 1% or +/- 1bpm,which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR
         Monitor: > 105 dB
         Operation: > 105 dB
         Diagnosis: > 85 dB

Electrode offset potential: +/-300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S  After Defi.

ECG Signal Range: +/- 8 m V ( Vp-p )

Bandwidth  

Surgery: 1 ~ 15 Hz

Monitor: 0.5 ~ 35 Hz

Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p),  Accuracy:+/-5% 

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,

          TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

RESPARATION

Method: Impedance between R-F(RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 – 2.5  KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

Adult: 0 ~ 120 rpm

Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy : ±2 rpm

Apean Alarm: 10 ~ 40 S

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range

  Adult Mode

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

  Pediatric Mode

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

    MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS: 40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Resolution Pressure:1mmHg

Accuracy  Pressure  Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

Adult Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg

SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy : 70% ~ 100% ±2 %

     0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy : +/-2bpm

TEMPERATURE

Channel: 1

Measuring and Alarm Range: 0 ~ 50 centigrade

Resolution: 0.1 centigrade

Accuracy : +/-0.1centigrade

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

IBP

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

ART: 0 ~ 300 mmHg

PA: -6 ~ 120 mmHg

CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

P1/P2: -10 ~ 300 mmHg

Press Sensor

Sensitivity: 5 uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy : +/-2% or +/-1mmHg, which great

Actualization interval: about 1 Sec

 