Measure Max Demands of kW, kvar, kva (sliding window)
CE MARK
Size: 80x80mm, 96x96mm, 120x120mm

1.General
          the measuement of all the 3 phase network data, specializes in measuring power MAX DEMANDs by sliding window method in every 15 minutes.It is widely applied in many power management systems. They comply EN 61326:2006 and EN 61010-1:2001.
          They are a kind of programmable analyzer. With the 4 key on the front, we can set their parameters according to the network which we measure. They have many option functions. They can be equipped RS-485 communication Modbus-RTU; or they can output analog signal. With logic input or logic output, we can realize controlling other equipment remotely
           They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system.

    

 

 

2.Technical Measure
- Measurement:       all the 3 phase data, MAX DEMAND of kW, kvar, kva

- Network:               3P3W, 3P4W
- Frequency:            45 ~ 65Hz
- Voltage:                AC 3x120/220V, 3x230/400V, 3x400V (programmable);

                              overload: 480V (continuous); 800V during 30s; Consumption: < 0.2VA
- Current:                AC 1A, 5A

                             Overload: 6A (continuous); 50A during 30s; Consumption: < 0.2VA
- Thermal drift:         <200ppm
- Transformation ratio: CT and PT ratio can be programmable
- Precision:             0.5 (F: 0.05Hz; kVar: 1)
- Power supply:       AC/DC 85 ~ 270V; Consumption < 4VA
- Test voltage:         2kVAC/min (voltage input / power; between current inputs); 1.5kVAC/min (outputs / power)
Insulation:               input / housing and output / housing >100M
- Work T:                -10C ~ +45C;Storage T: -20C ~ +70C
- Relative humidity:   5% ~ 95% (no condensation)
- Altitude:                < 2500m

           

 

 

3. Options
- Communication (/C) :    RS485 (Modbus-RTU);

                                     1 start bit, 8 data bit, 1 stop bit, no parity,

                                     speed (1200/2400/4800/9600/19200) 
- Alarm output(/J):           1 passive relay (1A/30VDC, 1A/250VAC):

                                     alarms of over voltage, low voltage and over current;

                                     The hysteresis and the delay can be set
- Analog output(/M):         DC4 ~ 20mA, DC0~20mA (load < 600Ω),

                                      DC0 ~ 5V,DC1 ~ 5V (load > 1kΩ)
- Logic options(/K):          2DI/2DO;

                                     DI: dry contact Input, supplied inside, optoisolator;

                                     DO: NO-NC contact; 1A/30VDC,5A/250VAC ( to control other equipments)