AFV series is a fixed mounted, transit-time ultrasonic Flowmeter, with clamp-on transducers for non-invasive liquid measurement.
GENERAL
ANJUN AFV series is a fixed mounted, transit-time ultrasonic Flowmeter, with clamp-on transducers for non-invasive liquid measurement.
Our microprocessor based, user friendly, field programmable flow measurement technique allows no interruption of the process flow and has low installation costs.
FEATURES
-2 line LCD display with flowrate, totalizer & signal condition
-Stores up 64 Day/Month/Year Totalizer daily value
-Batch control function
-Wide range velocities of 0.01 ~ ± 32 m/s
-Transducers for pipe size from 15 to 6000 mm
-High accuracy of ±1.0% of reading
-Transducers include magnet devise, for installation on metal pipe without
-Data logger function, include date, totalizer, signal condition... etc
-Response time less than 1 second
SPECIFICATION
Measuring Principle: Transit time difference
Pipe Size : S Type : 15 mm ~ 100 mm (1/2" ~ 4")
: M Type : 50 mm ~ 700 mm (2" ~ 28")
: L Type : 300 mm ~ 6000 mm (12" ~ 240")
: HS Type : 15 mm ~ 100 mm (½" ~ 4")
: HM Type: 50 mm ~ 1000 mm (2" ~ 40")
Pipe Material : Cast Iron, Stainless Steel, Ductile Iron
Copper, PVC, Aluminum, Fiberglass... etc.
Liner Material : Tar Epoxy, Rubber, Mortar, Polypropylene, Polystyrol, Polyethylene,
Teflon... etc
Display : 4 Line LCD with illumination.
Flowrate : 5 digit with decimal point
Totalizer : 8 digit, Forward, Reverse & Net values.
Engineer Unit : M3, Liter, US Gallon, Imperial Gallon, Million Gallon, Cubic Feet,
US Barrels, Imperial Barrels, Oil Barrel.
Time Unit : Second, Minute, Hour, Day.
Other : Velocity, Date, Time, Signal condition.
Accuracy : ± 1% ~ ± 2% of reading(0.5 ~ 30 m/s)
: ± 0.5% of reading (online calibration)
Repeatability : ±0.2% of reading
Temperature Input : 4-20 mA * 2 points for BTU calculation
Function : D T, Measurements for Thermal Energy
Keypad : 16 Key with tactile action
Response Time : Less than 1 second
Flow Velocity : 0.01 ~ ± 32 m/s
Resolution : 0.0001 m/s
Ambient Temperature : -20 ~ +50 °C
Mounting : wall mounting
Max. Cable Length : 150 M
Power Consumption : Less than 2W
Power Supply : 90 ~ 260Vac 50/60 Hz or 8-36Vdc
Data Storage : Operation parameters and totalization date are stored by EEPROM for more than 10 years
Output : 4-20 mA or 0-20 mA
Pulse Output : 1- 9999 Hz
Data Logger : 64 data include flowrate, totalizer, time, date.
Alarm : High/Low with buzzer
Communication : RS-232
Dimension : 251 * 192 * 80 mm
Weight : 3 Kg
Enclosure
Converter : IP65