HRC fuse for transformer protect
1.Material:porcelain
2.Length(mm):292,442,537; Diameter(mm):51,76,88
3.Certification: ISO900
Applications
H.V current-limiting fuses type S is mainly used in AC50Hz,rated voltage 3.6~40.5KV,rated current up to 200A circuit for protection transformers and power equipments from overload and short-circuit.It can also be used with load switch,vacuum contact.
It conforms to IEC282-1,GB15166.2 and DIN standard.
Design Features
S type H.V HRC current-limiting fuses is insert installation.The striker parallers to the fuse element made from pure silver. They are sealed in the fuse tube filled with chemically treated high-purity quartz sand. The fuse tube is made from heat resistance,high duty ceramic or expoxy glass.
When fault circuit happens, the fuse link melts, the high-resistant metal wire paralleling to fuse links melts immediately at the appearance of the arc, and the striker jumps out to push the chained equipment contact, signaling the melting automatically cuttig the circuit.
The striker has spring type striker jumps out to push ethe chained equipment contact, signaling the melting automatically cutting the circuit. The striker has spring type striker use high pressure caused by the lighting powder to push the striker.
S type H.V.HRC current-limiting fuses has many merits as high current-limiting ablilty, high breaking capacity, quick and punctual in action, reliable in performance.
Basic Data
Foreign model | Department | Rated voltage(KV) | Rated current(A) | Rated breaking current(KA) | Diameter(mm) D | Length(mm) L1 | Weight(kg) |
SDOAJ | XRNT1 | 3.6 | 6.3,10,16,20,25,31.5,40 | 31.5 | 51 | 192 | 1.12 |
SDLAJ | XRNT1 | 7.2 | 6.3,10,16,20,25,31.5,40,50,63 | 31.5 | 51 | 292 | 1.47 |
SFLAJ | XRNT1 | 7.2 | 80,100,125,160 | 31.5 | 76 | 292 | 3.15 |
SDLAJ | XRNT1 | 12 | 6.3,10,16,20,25,31.5,40 | 31.5 | 51 | 292 | 1.47 |
SFLAJ | XRNT1 | 12 | 50,63,71,80,100 | 31.5 | 76 | 292 | 3.15 |
SKLAJ | XRNT1 | 12 | 125 | 31.5 | 76 | 292 | 3.15 |
SXLAJ | XRNT1 | 12 | 160,200 | 31.5 | 88 | 292 | 4.15 |
SDMAJ | XRNT1 | 24 | 6.3,10,16,20,25,31.5,40 | 31.5 | 51 | 442 | 2.7 |
SFMAJ | XRNT1 | 24 | 50,63,71,80,100 | 31.5 | 76 | 442 | 4.5 |
SKMAJ | XRNT1 | 24 | 125 | 31.5 | 76 | 442 | 4.5 |
SXMAJ | XRNT1 | 24 | 160 | 31.5 | 88 | 442 | 5.4 |
SDQAJ | XRNT1 | 40.5 | 3.15,6.3,10,16,20,25 | 31.5 | 51 | 537 | 2.9 |
SFQAJ | XRNT1 | 40.5 | 31.5,40 | 31.5 | 76 | 537 | 5.51 |
SXQAJ | XRNT1 | 40.5 | 63 | 31.5 | 88 | 537 | 6.5 |
Note:under stipulated comdition,min.breaking current of fuses could be as high as 2.5~3 times than rated current.
Striker: N-without striker; A-powder type; D-spring type.
Welcome to contact us to more details. Some details could be ordered according to the requirement of customers.
Dimension drawing