Welcome to B2BAGE
Outdoor Type High-Voltage Drop-out Cutout Fuse 11kV 12kV, Expulsion Cut Out Fuse 11kV 12kV
Outdoor Type High-Voltage Drop-out Cutout Fuse 11kV 12kV, Expulsion Cut Out Fuse 11kV 12kV

Minimum Order: 0
Quality/Safety Certification: 0.00


1.Excellent current-breaking ability for fault current.
2.Outdoor AC HV drop-out fuse cutout.
3.Suitable for 10KV 11KV 12KV.

     The drop-out fuse cutout can offer overcurrent protection to the equipment which is easy to damage caused by system over-voltage or fault condition. In electrical distribution, a fuse cutout or cut-out fuse is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to melt, disconnecting the transformer from the line. It can also be opened manually by utility linemen standing on the ground and using a long insulating stick called a hot stick. Besides, the drop-out fuse cutout has advantages of flexibility, excellent property, convenient installation, long-term running without fault and long service life.

       Excellent current-breaking ability for fault current

       8KA/12KV, 12.5KA/12KV,16KA/12KV (at most four times)

Application scope

   1).100A fuse holder can hold fuse-link with rated current 6A-100A, while the 200A fuse holder  can hold fuse-link with rated current  100A-200A. In some special occasion, the fuse-link is chosen based on continuous overcurrent, the types of protective equipment and other demands of  overcurrent protective equipment. The types of protective equipment include circuit-breaker, recloser, other fuses and circuits.

   2). The fuse links used in most distribution cutouts are tin or silver alloy fuse links that melt (or operate) when exposed to high current conditions. The ampere ratings of fuse elements rated from 100 ampere to 200 amperes.

Standard

   The design and experiment for NCX type drop-out fuse conforms to the standard as follows:

    GB  15166.3

    DL/T 640

Structure of fuse cutout 

   1).  Fuse tube: is made of high intensity epoxy glass fiber pipe.

   2). The base of fuse cutout: the base is composed of embedded mechanical structure and insulator. The metal bar of the installation mechanical structure, which adheres to the insulator through special adhesive material, can bear power generated from breaking short circuit current.

Technical parameter

Product type

YDNCX-12/100-8               

YDNCX-12/200-12.5

Rated voltage

12kV

12kV

Rated current

100A

200A

Rated frequency

50Hz

50Hz

Breaking current

8kA

12.5kA

Power frequency withstand voltage (wet)

30kV

36kV

Power frequency withstand voltage (dry)

42kV

49kV

Rated light impulse voltage  

75kV

85kV

Impulse voltage (BIL)

125kV

125kV

Mechanical life (on/off time)

500 times

500 times

Height above sea level

Less than 1000m

Less than 1000m

Environment temperature

-40 to 70°C

-40 to 70°C

Leakage distance

372mm

372mm

Weight

6.6kg

6.6kg

Notice:

If the height above sea level exceeds 1000m, please contact manufacturer.

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ads by Google