it can be installed in an explosive or hazardous environment for gas detection.
The ZX-212 inflammable gas detection(SC910) and alarm controller can be extensively useful on many leakage-easy-to-happen occasions, indoors or outdoors, such as production, storage and usage of inflammable gases in the industry of chemicals, petroleum, metallurgy, oil tank farms, liquefied gas stations, spray-painting works, and gas transmission and distribution Can work with electrovalve&exhaust fan(optional)
SC-910, a point-type inflammable gas detector with measuring range of 0%100%LEL, can be installed in an explosive or hazardous environment for gas detection. The detector converts the concentration of an inflammable gas in the field into data signals transmitted to an inflammable gas alarm controller (main unit) in a non-hazardous area, meeting the demand for measuring on-site inflammable gas concentration,
An advanced microprocessor, which is characterized in high response speed, long MTPF, ability of long-period uninterrupted service and functions of automatically detecting probe failures and uploading alarm signals to the controller, is employed as the control unit of a SC610 point-type inflammable gas detector. The detector is in compliance with relevant national standards on electrical properties and has passed the certification inspection by China National Supervision and Test Center for Fire Electronic Product Quality. The design of the detector meets the requirements of related national regulations, thus having the certification of dIIBT6 awarded by China National Quality Supervision and Test Center for Explosion-Proof Electrical Products.
Principle of Sensing device | Catalytic combustion |
Sampling Type | Spontaneous diffusion |
Respondent Gases | Inflammable gases including natural gas, liquefied petroleum gas |
Service Voltage | DC24V |
Range of Working Voltage | DC12V-25V |
Wiring System | 485 bus system |
Temperature | -40°C~+70°C |
Relative Humidity | ≤93%RH |
Sound pressure range | ≥75dB/m |
Explosion Prevention Type | Explosion isolation type |
Class of Explosion Prevention | ExdIIBT6 |
Alarm Concentration | Primary alarm adjustable default 25%LEL; secondary alarm: 50%LEL |
Stability | Error for alarm concentration is not more than ±3%LEL |
Repetitiveness | Error for repetitiveness testing of alarm concentration is not more than ±3%LEL |
Error for Alarm Concentration | Not more than ±3%LEL |
Alarm Type | Uploading alarm signals through a 485 bus |
Executive Standard | GB15322.1-2003 |
Connection Steel Pipe |
Connector |