Name:Gas meter
1. 50 years experience
2. ISO:9001 :2008
3. High sensitivity
4. With many years of export experience
Name:Gas meter
FEATURES
1. Accurate measurement, the ex-works controlling index for the large and medium flowrates : ±1.2%
2. Rubber diaphragm adopts special material and its durability reach 3000 hours.
3. Adopting automatic glue applying technology and its leak tightness performance reaches 30 KPa.
4. Adopting surface electrophoretic coating treatment technology and it has strong corrosion resistance and long service life.
5. The sliding valve makes rotary displacement motion, there is regular friction and even wearing between the sliding valve and the seat of the sliding valve.
EXECUTION STANDARD
The products execute GB/T 6968-1997 diaphragm gas meter Grade B standard and JJG 577-2005 diaphragm gas meter standard and OIML R31-1995 diaphragm gas meter international ttandard, products’ durability executes Europe standard EN1359:1998, main technical index listed below is the actual inspection standard for meters to leave the factory.
Item | Unit | Model | |||
J1.6C | J2.5C | J4C | |||
Nominal flow-rate(Qn) | m3/h | 1.6 | 2.5 | 4 | |
Maximum flow-rate(Qmax) | m3/h | 2.5 | 4 | 6 | |
Minimum flow-rate(Qmin) | m3/h | 0.016 | 0.025 | 0.040 | |
Working pressure range | kPa | 0.5-30 | |||
Working environment temperature | °C | -20~50 (speciality : (-30~60) | |||
Average value of total pressure loss | Pa | ≤160 | |||
endurance | h | 2000 | |||
Maximum permissible error | Qmin≤Q<0.1Qmax | % | ±3 | ||
0.1Qmax≤Q≤Qmax | % | ±1.5 | |||
Max cumulative reading figures | m3 | 9999 | 99999 | ||
Weight | kg | 1.8 | |||
Meter fittings joint threading |
| M30×2 | |||
Meter fittings central distance | mm | 130 |