Welcome to B2BAGE
3.91kw~9.05kw Domestic Monobloc Air to Water Heat Pumps
3.91kw~9.05kw Domestic Monobloc Air to Water Heat Pumps

Minimum Order: 0
Quality/Safety Certification: 0.00


Panasonic/Mitsubishi compressor with R410A gas;
Tube-in-shell heat exchanger;
WILO circulation pump;
CE, CB, IEC.

ModelYASBP-25HLYASBP-38HLYASBP-50HLYASBP-56HLYASBP-90HL
Measuring Condition (A20/W15~ W55°C)Heating Capacitykw3.915.15.747.539.05
Power Inputkw0.81.2141.3241.882.61
Running CurrentA3.645.316.148.711.86
COP 4.894.204.304.014.21
Hot Water OutputL/h86110130165210
Power SupplyV/PH/Hz220V/1ph/50Hz220V/1ph/50Hz220V/1ph/50Hz220V/1ph/50Hz220V/1ph/50Hz
Heating Max Power Inputkw1.21.72.222.233.987
Heaing Max CurrentA5.577.7510.0910.3218.12
Cooling Max Power Inputkw0.91.31.6871.93.014
Cooling Max CurrentA4.286.27.67913.7
Refrigerant R410AR410AR410AR410AR410A
Refrigerant Weightkg550g650g700g720g980g
Compressor  PANASONICPANASONICPANASONICPANASONICPANASONIC
Compressor RotaryRotaryRotaryRotaryRotary
Compressor Qty. 11111
Fan Motor Model YDK-18-6l1CYDK-30-6YDK-30-6YDK-30-6YDK-50-6
Fan Power InputW1830303050
Fan SpeedRPM910900900900890
Fan Cover Round & BlackRound & BlackRound & BlackRound & BlackRound & Black
Noise (tested from 1 meter away)dB(A)≤48≤48≤48≤48≤48
Heat Exchanger Tube-in-ShellTube-in-ShellTube-in-ShellTube-in-ShellTube-in-Shell
Water Connectionmm3/4"3/4"3/4"3/4"3/4"
Water Flow Ratem3/h1.81.81.81.81.8
Water Pressure Dropkpa2020202020
Throttling Device Capillary TubeCapillary TubeCapillary TubeCapillary TubeCapillary Tube
Controller  Intelligent & LCDIntelligent & LCDIntelligent & LCDIntelligent & LCDIntelligent & LCD
Controller Linem1212121212
Net Dimension (L/W/H)mm770/300/490940/360/550940/360/550940/360/5501010/370/615
Packing Dimension (L/W/H)mm820/325/520985/390/590985/390/590985/390/5901140/400/670
Net Weight / Gross Weingtkg38/4351/5655/6058/6365/70
Loading Qty. (20"/40"/40HQ)Unit218/450/500126/265/290126/265/290126/265/29087/183/244
Protection Device High/Low pressure protection, Hydraulic protection, overload protection, freezing protection, temperature protection

Standard test condition: Dry/Wet Bulb Temp.: 20°C/15°C; Water Inlet/Outlet Temp.: 15°C/55°C.

 

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.