Heat Pump Three In One Unit:
Five modes: Hot water; Heating; Cooling; Heating + Hot water; Cooling + Hot water.
Heat Pump Three In One Unit:
Series | J | |||||||
Model |
|
| KS-11J1 | KS-11J1A | KS-18J1 | KS-18J1A | KS-36J2 | |
Power supply(V/Ph/Hz) |
| 220-240/1/50 | 380/3/50 | |||||
Hot water model | Heating capacity | kw | 10.7 | 10.7 | 17.5 | 17.5 | 35 | |
Rated power input | kw | 2.6 | 2.6 | 4.1 | 4.1 | 8.2 | ||
COP |
| 4.1 | 4.1 | 4.3 | 4.3 | 4.3 | ||
Hot water output | L/h | 230 | 230 | 375 | 375 | 750 | ||
Floor heating model | Heating capacity | kw | 8.5 | 8.5 | 14 | 14 | 28 | |
Rated power input | kw | 2.3 | 2.3 | 3.8 | 3.8 | 7.6 | ||
COP |
| 3.7 | 3.7 | 3.7 | 3.7 | 3.7 | ||
Fan coil heating model | Heating capacity | kw | 8 | 8.0 | 13.0 | 13.0 | 27.0 | |
Rated power input | kw | 2.65 | 2.65 | 4.35 | 4.35 | 8.90 | ||
COP |
| 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | ||
Cooling mode | Cooling capacity | kw | 7.5 | 7.5 | 12 | 12 | 24 | |
Heat recovery capacity | kw | 9 | 9.0 | 14 | 14 | 28 | ||
Rated input power | kw | 2.6 | 2.6 | 4.1 | 4.1 | 8 | ||
EER |
| 6.3 | 6.3 | 6.3 | 6.3 | 6.5 | ||
Circulating water flow volume | m3/h | 1.3 | 1.3 | 2.1 | 2.1 | 4.2 | ||
Hot water temperature | °C | 20~55(reach 80°C on heating+hot water / cooling+hot water model) |
| |||||
Compressor type |
|
| Rotary |
| Scroll |
|
| |
Refrigerant |
|
| R407C |
|
|
|
| |
Noise |
| dB(A) | 58 | 58 | 58 | 58 | 64 | |
Net weight |
| kg | 102 | 87 | 134 | 128 | 316 | |
Unit dimensions |
| mm | 960×340×1260 | 755×755×680 | 960×340×1260 | 755×755×980 | 1390×740×1640 | |
Packing dimensions |
| mm | 1100×480×1350 | 780×780×720 | 1100×480×1350 | 780×780×1020 | 1490×790×1800 | |
Stacking layers |
| layer |
| 3.0 | 2 | 2 | 1 | |
Water pipe connector | mm | DN25(1) | DN25(1") | DN32(1-1/4") | DN32(1-1/4") | DN40(1-1/2") | ||
Ambient condition | °C | -10~43 |
|
|
|
| ||
Picture of appearance |
| Picture 1 | Picture 2 | Picture 1 | Picture 3 | Picture 4 | ||
1)Water heater rated test conditions: Ambient temp.(DB/WB): 20°C/15°C,Initial water temp. 15°C,temp. rise 40°C. 2)Floor heating rated test conditions:Ambient temp.(DB/WB): 7°C/6°C,Water temp.(In/Out):30°C/35°C. 3)AC heating rated test conditions:Ambient temp.(DB/WB): 7°C/6°C,Water temp.(In/Out):40°C/45°C. 4)AC cooling rated test conditions:Ambient temp.(DB/WB): 35°C/24°C,Water temp.(In/Out):12°C/7°C. Heat recovery water temp.(In/Out):40°C/45°C. 5)If the product improvement brings to the change of the parameters ,please refer to the nameplate. |