fan coil units
1,air volume flow:180m3/h--2380m3/h
2,Rating cooling capacity:1430-12600W
3,Rating heating capacity;2160-18900
fan coil units
Performance Parameters Table of the CYFC( WM, LM Series) Fan Coil Unit
Type | Corporation standard(CYFC) | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1400 | |
Parameters | State standard(FP) | 34 | 51 | 68 | 85 | 102 | 136 | 170 | 204 | 238 | |
Rated Air Flow Volume(m3/h) | High-gear | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium-gear | 260 | 390 | 520 | 650 | 780 | 1040 | 1290 | 1580 | 1820 | ||
Low-gear | 180 | 270 | 360 | 450 | 530 | 710 | 890 | 1060 | 1240 | ||
Rated Cooling Capacity(W) | High-gear | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | |
Medium-gear | 1620 | 2450 | 3240 | 4050 | 4850 | 6480 | 7980 | 9580 | 11200 | ||
Low-gear | 1430 | 1990 | 2650 | 3220 | 3820 | 5140 | 6400 | 7480 | 8960 | ||
Rated Heating Capacity(W) | High-gear | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | |
Medium-gear | 2450 | 3680 | 4860 | 6120 | 7275 | 9980 | 11960 | 14200 | 16520 | ||
Low-gear | 2160 | 3240 | 4300 | 5200 | 6400 | 8600 | 9200 | 10800 | 12960 | ||
Outlet Static Pressure(Pa) | 12 | ||||||||||
Motor | Power | Monophase 220V 50Hz | |||||||||
Power Output | 8 | 12 | 16 | 25 | 40 | 16*2 | 25*2 | 40*2 | 50*2 | ||
Power Input | 34 | 41 | 59 | 73 | 91 | 118 | 146 | 182 | 216 | ||
Fan | Type | Double air inlet multi-blade anteversing centrifugal fan | |||||||||
Number | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Coil | Type | Copper pipe shrouded with aluminum sheet | |||||||||
Maximun working pressure | 1.6MPa | ||||||||||
Piping | Supply water pipe | 3/4Internal thread | |||||||||
Condensate water pipe | 3/4Exterior thread | ||||||||||
Water flow volume(kg/h) | 360 | 520 | 680 | 780 | 920 | 1280 | 1580 | 1860 | 2160 | ||
Water resistance(kpa) | 7 | 15 | 18 | 23 | 28 | 30 | 22 | 30 | 36 | ||
Noise dB(A)(Air flow volume at high-gear) | 35 | 36 | 38 | 40 | 43 | 44 | 45 | 48 | 49 | ||
Unit weight (kg) | WM Series | 26 | 29 | 34 | 38 | 44 | 58 | 62 | 65 | 73 | |
LM Series | 28 | 31 | 36 | 39 | 43 | 54 | 59 | 63 | 71 | ||
Note: Datas in the table is the testing values in experimental working condition regulated by state standard Fan Coil Unit(GB/T19232-2003) 1. Parameters in cooling working condition: Dry-bulb temperature DB=27,wet-bulb temperature WB=19.5, inlet chilled water temperature 7, outlet water temperature 60. Parameters in heating working condition: Inlet air dry-bulb temperature DB=21, inlet water temperature 60 2. Noise testing: Values tested 1m away from around the unit, in the dead room. |