Welcome to B2BAGE
Hvac products:fan coil
Hvac products:fan coil

Minimum Order: 0
Quality/Safety Certification: 0.00


fan coil units
1,air volume flow:180m3/h--2380m3/h
2,Rating cooling capacity:1430-12600W
3,Rating heating capacity;2160-18900

fan coil units

Performance Parameters Table of the CYFC( WM, LM Series) Fan Coil Unit

Type

Corporation standard(CYFC)

200

300

400

500

600

800

1000

1200

1400

Parameters

State standard(FP)

34

51

68

85

102

136

170

204

238

Rated Air Flow Volume(m3/h)

High-gear

340

510

680

850

1020

1360

1700

2040

2380

Medium-gear

260

390

520

650

780

1040

1290

1580

1820

Low-gear

180

270

360

450

530

710

890

1060

1240

Rated Cooling Capacity(W)

High-gear

1800

2700

3600

4500

5400

7200

9000

10800

12600

Medium-gear

1620

2450

3240

4050

4850

6480

7980

9580

11200

Low-gear

1430

1990

2650

3220

3820

5140

6400

7480

8960

Rated Heating Capacity(W)

High-gear

2700

4050

5400

6750

8100

10800

13500

16200

18900

Medium-gear

2450

3680

4860

6120

7275

9980

11960

14200

16520

Low-gear

2160

3240

4300

5200

6400

8600

9200

10800

12960

Outlet Static Pressure(Pa)

                        12

 

Motor

Power

    Monophase  220V  50Hz

Power Output

8

12

16

25

40

16*2

25*2

40*2

50*2

Power Input

34

41

59

73

91

118

146

182

216

Fan

Type

Double air inlet multi-blade anteversing centrifugal fan

Number

1

2

2

2

2

3

4

4

4

Coil

Type

Copper pipe shrouded with aluminum sheet

Maximun working pressure

1.6MPa

Piping

Supply water pipe

3/4Internal thread

Condensate water pipe

3/4Exterior thread

Water flow volume(kg/h)

360

520

680

780

920

1280

1580

1860

2160

Water resistance(kpa)

7

15

18

23

28

30

22

30

36

Noise dB(A)(Air flow volume at high-gear)

35

36

38

40

43

44

45

48

49

Unit weight

(kg)

WM Series

26

29

34

38

44

58

62

65

73

LM Series

28

31

36

39

43

54

59

63

71

Note: Datas in the table is the testing values in experimental working condition regulated by state standard Fan Coil Unit(GB/T19232-2003)

1.      Parameters in cooling working condition: Dry-bulb temperature DB=27,wet-bulb temperature WB=19.5, inlet chilled water temperature 7, outlet water temperature 60.

Parameters in heating working condition: Inlet air dry-bulb temperature DB=21, inlet water temperature 60

2. Noise testing: Values tested 1m away from around the unit, in the dead room.

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.