LMT01 mechanical Room thermostat for central air conditioner
1.ON-OFF switch
2.3-speed switch
3.Heating-cooling switch
LMT01 mechanical Room thermostat for central air conditioner
Item No. | Rated Voltage | Load current | Range | Temp.difference | N.W(kg) |
LMT01A/MT01AF
| 230V±10%AC 110V±10%AC 24V±10%DC | ≤3A | 10°C~30°C 5°C~35°C | ±1°C(25°C) | 183 |
LMT01B/MT01BF
| 10°C~30°C | 190 | |||
8°C~30°C | 180 | ||||
LMT01E/MT01EF |
Technical parameter:
Power voltage:AC24,110V,230V(220V),50HZ-60HZ.
Load current:<3A
Temperature-sensitive component:gas-filled diaphragm.
Environment temperature:-5-50degree.
Temperature differential:<=1degree (in 25 degree)
Shell protection:IP20 shell material:anti-flame ABS/PC.
Temperature-setting driver plate,the pointer means the required constant temperature.
System starter,ON/OFF means to connection/disconnection respectively for the power of thermostat.
Low-Medium-high(If it is fan valve controller,this function is not available)
Mechanical transmitting component with reliable structure can satisfy the requirment of being used in more harsh environment.
Model | Controlled object | Explaination | Applicable system | ||||||
MT01AE | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed,the fan will | water system | |||||||
speed FCU | operate according to the selected speed | ||||||||
MT01AE1 | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed | water system | |||||||
speed FCU | |||||||||
MT01BE | 3 wire motorized | When environment temperature reach to setting | Four-tube standard | ||||||
vale,motorized ball value | value,the motorized valve is closed,the fan will operate according to the selected speed | water system | |||||||
and 3 speed FCU | |||||||||
MT01AS | 3 wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
vale,motorized ball value | value,the motorized value is closed,the fan will | water system | |||||||
and 3 speed FCU | operate according to the selected speed | ||||||||
MT01AS1 | 3 wire motorized | When environment temperature reach to setting | Four-tube standard | ||||||
vale,motorized ball value | value,the motorized value is closed,the fan will | water system | |||||||
and 3 speed FCU | operate according to the selected speed | ||||||||
MT01BS | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed,the fan will | water system | |||||||
speed FCU | operate according to the selected speed | ||||||||
MT01AE2 | 3 wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
vale,motorized ball value | value,the motorized value is closed,the fan will | water system | |||||||
and 3 speed FCU | operate according to the selected speed | ||||||||
MT01AS2 | Fan mouth of motor of | According to the difference between in-house temperature and | |||||||
motorized fan valve | setting temperature,closing or opening motorized fan valve is | Fan system | |||||||
controlled by the thermostat automatically | |||||||||
MT01F | Two-wire motorized | When environment temperature reach to setting | Two-tube standard | ||||||
valve and three | value,the motorized value is closed,the fan will | water system | |||||||
speed FCU | operate according to the selected speed |
The pictures show the quality