Welcome to B2BAGE
Rebar Locator
Rebar Locator

Minimum Order: 0
Quality/Safety Certification: 0.00


DJGW-2A is Rebar Locator, quickly and easily detect the location of various structures within the steel, protective layer .

Rebar Locator - DJGW-2A

 

   DJGW-2A is a series of reinforcing bars, construction-site meter testing equipment, both quickly and easily detect the location of various structures within the steel, protective layer thickness, reinforcement spacing, bar diameter, and can accurately draw the overall reinforcement of the distribution, to provide accurate test data.

 

Detection Principle:
Super anti-jamming capability of the electromagnetic pulse method of nondestructive testing

Instrument features:

-digital, analog display double the amount of magnetic flux density, multi-parameter sensor.
-protective layer thickness and the reinforcement signal real-time image display, and store the minimum auto-lock action, the operation more convenient.
-level dual range mode, a valid test to ensure accuracy and depth of the probe.
-no-border sections, the grid scan mode, can automatically measure and record the reinforcement spacing, the distribution of real-time display of reinforced concrete.
-precision steel intensive testing.
-display backlight design.
-powerful data processing capabilities, test data can view the scene.
- professional data analysis software, and connected to a PC can be automatically generated and printed after the test report.

 

Main features:
Detection of reinforcing bars, steel cover thickness and diameter, also has:
  1 grid measurement, continuous scanning in both directions, showing distribution of steel mesh;
  2 profiling technique, a continuous direction, showing distribution of steel profiles;
Instrument has a powerful data processing capabilities, with the windows PC, special software can graphically display the cross-section and steel trellis.

 

Technical parameters:
-Scope: φ6-φ50;
-Protective layer measurement accuracy :6-79mm, error ≤ ± 1mm; 80-119mm, error ≤ ± 2mm; 120-190mm, error ≤ ± 4mm;
-Bar diameter measurement accuracy: ≤ ± 1 error specifications (correct size);
-Steel positioning accuracy: error ≤ ± 3mm;
-LD display: 124 × 80 (mm); Power: 9VDC60 5 # battery);
-Operating temperature: -10 º -40 °C; Humidity: <90%;
-Weight: 0.7kg; Size: 220 × 180 × 80 (mm)
-Grid scan range: 10m × 10m
-Standard Probe: 110 × 55 × 28 (mm); ranging car: 135 × 75 × 53 (mm)

 

 Standard configuration:

  Host ,ranging car ,standard probe ,probe connection/distance line ,software CD-ROM.

 

 

 

 

 