MFD800B Ultrasonic Flaw Detector

Ultrasonic flaw detector MFD800B
MFD800B can be widely used in locating&sizing hidden cracks,voids,disbands,and similar discontinuities in welds,forgings,billets,axles,shafts,tanks&pressure vessels,turbines,and structural components.

Display
Hi-resolution (640×480 pixels) multi-color TFT LCD with 4 user-selectable brightness control provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness.
The hi-resolution multi-color TFT LCD display with fast 60 Hz update gives an “analog look” to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.
Range
Up to 9999 mm in steel. suitable for use on large work pieces and in
high-resolution measurements.
Pulser
Pulse Energy selectable among Low, Medium and High.
Pulse Width tunable from 0.1μs to 0.5 μs to match the probes with different
frequency.
Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz
increments.
Damping selectable among 100Ω,200Ω and 400Ω for optimum probe
performance
Test Modes include Pulse echo, dual and thru-transmission
Receiver
Sampling:10 digit AD Converter at the sampling speed of 160 MHz
Rectification:Positive Halfwave, Negative Halfwave, Fullwave and RF
Analog Bandwidth:0.5MHz to 15MHz capability with selectable frequency
ranges (automatically set by the instrument) to match probe for optimum
performance.
Gain:0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and
locked.
Gate
Two fully independent gates offer a range of measurement options for signal height or distance using peak triggering.
The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.
Gate Start:Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 0 to 99% Full Screen Height
Alarms: Threshold positive/negative
Memory
Memory of 1000 channel files to store calibration set-ups
Memory of 10000 wave files to store A-Scan patterns and instrument settings.
All the files can be stored, recalled and cleared.
Video Recorder
Screen scenes can be captured as movie files. More than 10 hours movie can be saved to the inside memory. They can be re-played using the instrument or the PC software delivered with the instrument.

Video Recorder is useful in many situations, it is very convenient for those who want to analyze the probing activities later.
Function
-Semiautomatic two point calibration: Automated calibration of transducer zero offset and/or material velocity
- Flaw Locating:Live display Sound-path, Projection (surface distance), Depth, Amplitude,
- Flaw sizing: Automatic flaw sizing using AVG/AVG or DAC, speeds reporting of defect acceptance or rejection.
- Digital Readout and Trig. Function: Thickness/Depth can be displayed in digital readout when using a normal probe and Peam path, Surface
- Distance and Depth are directly displayed when angle probe is in use.
- Both the DAC and the AVG method of amplitude evaluation are available.
- TVG(Time Varied Gain).
- AWS D1.1.
- Curved Surface Correction feature
- Crack Height Measure function
- Weld figure feature
- Magnify gate:spreading of the gate range over the entire screen width
- Video Recording and play

- Auto-gain function
- Envelope: Simultaneous display of live A-scan at 60 Hz update rate and envelope of A-scan display
- Peak Hold: Compare frozen peak waveforms to live A-Scans to easily interpret test results.
- A Scan Freeze:Display freeze holds waveform and sound path data
- B Scan display feature
Real Time Clock
The instrument clock keeps running tracking the time.
Communication
High speed USB2.0 port. Two USB modes can be selected: U-DISK na U-BRIDGE. In U-DISK mode, the instrument acts as a usb flash disk when connected with pc. Configuration files, saved pictures and recorded movies can be copied to pc when possible. In U-BRIDGE mode, the instrument exchanges data with DataPro Software. The optional DataPro software helps manage and format stored inspection data for high-speed transfer to the PC.
Data can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.
Battery
Internal rechargeable Li-ion battery pack rated 7.2V at 6600 mAh
8 hours nominal operating time depending on display brightness
8-10 hours typical recharge time
Knob
Operating adjustments are easily and quickly made using the rotary knob.
Specification
- Range: 0 to 9999 mm, at steel velocity
- Material Velocity: 1000 to 9999m/s
- Display Delay: -20 to 3400 μs
- Probe Delay/Zero Offset : 0 to 99.99μs
- Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
- Test Modes: Pulse echo, dual element and thru-transmission
- Pulser: Tunable Square Wave Pulser
- Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
- Pulse Energy: Low, Medium and High
- Damping: 100, 200, 400 ohms
- Bandwidth (amplifier bandpass ): 0.5 to 15 MHz
- Gate Monitors: Two independent gates controllable over entire sweep range
- Rectification: Positive halfwave, negative halfwave, fullwave, RF
- System Linearity: Horizontal: +/-0.2% FSW, Vertical: 0.25% FSH, Amplifier Accuracy +/-1 dB.
- Reject (suppression): 0 to 80% full screen height
- Units: Inch or millimeter
- Transducer Connections: BNC or LEMO
- Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
- Operating Temperature: -10°C to 50°C
- Storage Temperature: -30°C to 50°C