small dimension open frame, competitive price, CUL/UL/CB/CE approvals, medical type
MODEL | MPS-30-27 | |
OUTPUT | DCVOLTAGE | 27V |
| RATEDCURRENT | 1.1A |
| CURRENTRANGE | 0~1.1A |
| RATEDPOWER | 30W |
| RIPPLE&NOISENOTE.2 | 240mVP-P |
| VOLTAGETOLERANCE | +/-3.0% |
| LINEREGULATION | +/-1.0% |
| LOADREGULATION | +/-2.0% |
| SETUP.RISEHOLD.TIME | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
INPUT | VOLTAGERANGE | 88~264VAC auto switch 120~370VDC |
| FREQUENCYRANGE | 47~63HZ |
| EFFICIENCY | 78% |
| AC CURRENT | 0.8A/115VAC 0.4A/230VAC |
| INRUSH CURRENT | COLD START 30A/230VAC |
| LEAKAGECURRENT | <0.3mA / 264VAC |
PROTECTION | OVER LOAD | Above 105% rated output power |
|
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| OVER TEMPERATURE | Tj 135 typically (U1) detect on main control IC |
|
| Protection type : Shut down o/p voltage, re-power on to recover |
| OVER VOLTAGE | 29.7~36.45V |
|
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
ENVIRONMENT | WORKINGTIMP | -10~+600C (Refer to output load derating curve) |
| WORKINGHUMIDITY | 20 ~ 95% RH non-condensing |
| STORAGE TEMP HUMIDITY | -20~+850C 10~95%RH |
| TEMPCOEFFICIENT | +/-0.03%(0~500C) |
| VIBRATION | 10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes |
SAFETY&EMC | SAFETYSTANDARDS | UL2601-1,TUV EN60601-1,IEC60601-1 approved |
| WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:SHORT |
| ISOLATIONRESISTANCE | 1/P-0/P:>100M Ohms/500VDC/25°C/70%RH |
| EMI CONDUCTICN& RADIATION | Compliance to EN55011 (CISPR11) Class B |
| HARMONICCURRENT | Compliance to EN61000-3-2 ClassC(>/=75%load);EN61000-3-3 |
| EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteriaA |
OTHERS | MTBF | 547Khrs min. MIL-HDBK-217F (250C) |
| DIMENSION | 101.6*65.8*23.5mm (L*W*H) |
| PACKING | 0.16Kg; 90pcs/15.8Kg/1.02CUFT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to .EMI testing of component power supplies.. (as available on http://www.meanwell.com) |