Industrial NDT film(12x15in)
Industrial NDT film(12x15in)

Minimum Order: 0
Quality/Safety Certification: 0.00


Industrial NDT film(12x15in)
1.NDT(roll film)
2. using x-or gamma ray.
3.EN 584-1( class 3),ASTME 1815(class l)
5.ISO

Industrial NDT film(12*15in)

 

Brief description:

* Rivena Q4 is a kind of Industrial Radial Films; make NDT to the object by using x-ray or gamma ray.

* Rivena Q4 is an ideal and wide applied with its characteristics as medium sensitivity, high contrast, high clarity and utmost meticulous texture;

* According to EN-584-1 standard, Rivena Q4 accord with C3 category;

* According to ASTM E1815 standard, Rivena Q4 accord with I category

 

 

Application field:

 

* Rivena Q4 can be used to take x-ray image for medium thin-wall steels /products, under low voltage. If under high voltage, it is suitable to conduct detection for medium thin-wall steels.

* Rivena Q4 is suitable to detect thick-wall and high density steels /products through high-energy gamma ray.

 

Application Objects:

*Metal, Castings, Fiber

*Aircraft Industries, Electron component

*Nuclear industry, Piping, Welding

 

Film base

 

Rivena Q4 is made under light blue stable-size PET base, the thickness is 0.175mm.

 

Darkroom lighting

 

Rivena Q4 should be operated under indirect safelight lamp (wavelength>520nm). Suggest use Agfa R1 filter (dark red) or Agfa G7 filter (olive green) installed with 25W safelight bulk, and place it at least 75cm distance between the reflecting surface and films, or use LED light (wavelength660nm—590nm)

 

Developing

* Rivena Q4 is suitable for both of automatic and manual developing. Suggest use Rivcha developer &fixer

* Manual (developing time 5 minutes, temperature 20°C) FOMADUX LP –T

* Automatic(developing time 120 seconds, temperature 28°C) FOMADUX LP-D

* Rivena Q4 also can be developed by other supplier’s chemicals

 

Emulsion features

Material from ISO2(220kV/10mA/8mm Cu) auto-developing, FOMA developer and fixer, processing time :8minutes ,temperature: 28°C,matches with developing soaking time 120 seconds

 

 

Exposed films record

Manufacturer guarantees the record time for permanent film as 50 years, but should observe follow term:

* Films should be developed cleanly and with best photographic fixing.

* Films should be stored under the relative humidity condition between 30%--60% and away from harmful gas.

 

Storage for unexposed films

 

Unexposed Rivcha series films should be stored into original light-tight package and in dry place, low temperature as much as possible, keep away from aggressive steam & gas, harmful gas and any other ionizing radiation. The ideal storage temperature should be 5°C--21°C, Air humidity 40%--60%. Dispose the exposed film as soon as possible.

 

 

Steels exposing chart

 

Condition : Optical density: D=2,  front-back lead & platinum screen:0.025mm, FOMA developer & fixer, temperature: 20°C, time: 5 minutes.

 

 

 

 