Rated Power:4000W
Output Frequency: 50Hz/60Hz
Charge Current:15A (Max)
Prostar 7000 Series Inverter
→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→
Applied Scope
Office Automation
Medical & Education
Industrial Automatic Control
Electronic & Telecom
Data Center
Finance & Securities
Production Equipment
Broadcasting & Transportation
Main Characteristics
1) Advanced all-digital control
2) Intelligent Charger
3) With strong load performance and wide application range
4) Special Protection method
5) High Efficiency and Energy Saving
6) Well unattended function
→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→
Telchnical Specification
Model | AN0K3 | AN0K5 | AN1K | AN1K5 | AN2K | AN3K | AN4K | AN5K | AN6K | AN8K | AN10K | |||||
Rated Power | 300W | 500W | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10000W | |||||
Battery Voltage | 12V | 24V | 48V | 96V | ||||||||||||
Charge Current | 15A (Max) | |||||||||||||||
Transfer Time | 5ms | 1s | ||||||||||||||
Size (WxDxH)mm | Chassis | 375x130x190 | 452x192x338 | 500x260x455 | 630x264x760 | |||||||||||
Inner Packing | 480x235x305 | 575x325x480 | 535x335x520 | 670x340x840 | ||||||||||||
Outer Packing | 495x490x320(2Pcs) | 584x335x495 | 545x345x535 | 680x350x850 | ||||||||||||
Weight (Kg) | Net Weight | 6.5 | 10 | 13.2 | 17 | 26.1 | 29.5 | 32 | 36 | 42 | 47 | 50 | ||||
Inner packing Gross Weight | 7.4 | 10.9 | 14.1 | 18.8 | 28.6 | 32 | 35 | 39 | 45 | 50 | 50 | |||||
Outer Packing Gross Weight | 15.6 | 22.6 | 29 | 19.7 | 30 | 33.4 | 37 | 39 | 45 | 50 | 50 | |||||
Input | Voltage | 100/110/120/127/220/230 VAC (+25%,-50%) | ||||||||||||||
Frequency | 50Hz/60Hz | |||||||||||||||
Output | Voltage | 100/110/120/127/220/230 VAC ±10% | ||||||||||||||
Frequency | Main power mode: same frequency Inverter mode: 50Hz/60Hz± 0.5 | |||||||||||||||
Wave Form | Sine Wave | |||||||||||||||
Display | LED/LCD | Standard/ Optional | ||||||||||||||
Protection | Charge | By TOP charging, speed up the battery charging speed, extend battery life | ||||||||||||||
Overload | When loading over 120%, the UPS will shut sown automatically in 10 seconds. When the load recovered, the UPS will resume output automatically. | |||||||||||||||
Short-circuit | Output short-circuit, the UPS automatically shut down output, The machines automatically resume output after troubleshooting. | |||||||||||||||
Battery Low | The UPS automatically shut down, it will charge automatically when main power recovered. |