variable speed drive for pump
variable speed drive for pump

Minimum Order: 0
Quality/Safety Certification: 0.00


1 PID control function
2 One frequency inverter drive more than one motor
3With ISO/CE/CCC Certification
4RS485 interface

ZY-P800F Fan and pump series(0.75-450KW)

With advanced functions of Time Period Control and PID adjusting. The running mode has single-pump mode, fixed mode of 1 drive controlling 2 pumps, rotating mode of 1 drive controlling 2 pumps, fixed mode of 1 drive controlling several pumps and rotating mode of 1 drive controlling several pumps. ZY-P800F series are effectively applied on the field of fan and pump loads.

 

Main function

. Single-pump mode: 1 drive controls one pump by PI adjusting.

. Fixed mode of 1 drive controlling n pumps;1 drive controls n pumps. One pump controlled by AC drives is called as frequency-conversion pump. The drive controls frequency-conversion pump by PI adjusting. The other pumps are connected with commercial power supply. The starting or stopping of these pumps are controlled by AC drives. These pumps are called as pumps of commercial power supply.

. Interchanging mode of 1 drive controlling n pumps : n pumps are interchanged to connect with the drive for a fixed period of time. After the interchanging time, frequency-conversion pump will be changed to pump of commercial power supply, and one pump of commercial power supply will be changed to the frequency-conversion pump.

. Circulating mode of 1 drive controlling n pumps : AC drives start or stop water pumps circularly according to PID feedback pressure. First start one pump, then stop one pump.

. Several speed control modes: PID adjusting, jogging control, analog control, digital setting control, PC/PLC control by MODBUS, and so on.

. The function of starting and stopping pumps controlled by different time period: users can set at most 6 time periods to control pumps started or stopped.

. Stage speed control in different time period: users can set at most 6 time periods of stage speed.

. Two-line type, three-line type operation control: terminal speed control is more convenient.

. Other functions: DC braking, rich displaying functions (In the stopping status, pressure value and present sensor input value are displayed by switching over mode. When clock function is on, present time can be displayed) and conversion function of daylight saving time.

 

Technical Specifications for F2000-P Series

Items

Contents

Input

Voltage Range

3-phase 400V±15%;

Frequency Range

50/60Hz

Output

Voltage Range

3-phase 0~400V

Frequency Range

0.00~60.0Hz (Frequency resolution is 0.01Hz )

ControlMode

Carrier Frequency

1600~10000Hz; random carrier frequency

Input Frequency Resolution

Digital setting: 0.01Hz, analog setting: max frequency 0.1%

Control Mode

V/F control

Overload Capacity

120% rated current, 60 seconds, 150% rated current, 10 seconds.

Torque Elevating

Manual Torque Promotion 0.1%~30.0% (V/F)

V/F Curve

3 kinds of modes: beeline type, square type and under-defined V/F curve.

DC Braking

DC braking frequency: 1.0~5.0 Hz, braking time: 0.0~10.0s

Automatic Voltage Rectification (AVR)

Enable to keep output voltage constant automatically in the case of change of grid voltage.

Operation Function

Frequency Setting

Potentiometer or external analog signal; keypad (terminal) keys, external control logic and auto-circulating setting, PC/PLC setting.

Start/Stop Control

Terminal control, keypad control or PC/PLC control.

Running Command Channels

3 kinds of channels from keypad panel, control terminal and PC/PLC.

Frequency Source

Given digit, given analog voltage, given analog current, given PC/PLC, PI adjusting and stage speed control.

Accessorial frequency Source

Given digit, given analog voltage, given analog current, PI adjusting and stage speed control.

Protection Function

Input out-phase, input under-voltage, over-voltage, over-current, AC drives over-load, motor over-load, over-heat, motor detection fault, external equipment fault, external disturbance, water lack protection, pressure protection, line disconnection protection.

Display

LED nixie tube showing present output frequency, present time, present flow of water, present output current, present output voltage, types of faults and parameters; Four LED indicators showing the current working status of AC drives.

Environment Conditions

Equipment Location

In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic gases, flammable gases, steam or the salt-contented, etc.

Environment Temperature

-10degrees centigrade~+50 degrees centigrade

Environment Humidity

Below 90% (no water-bead coagulation)

Vibration Strength

Below 0.5g (acceleration)

Height above sea level

1000m or below

Applicable Motor

0.75~450KW

 