1.Fuse was built-out
2.Maximum Constant Power Start at 120% rated power continue 10s
3.Remote control
4.Terminals isolated
MODEL No. SR300-112 RS300-124 RS300-212 RS300-224
AC VOLTAGE 100 / 110 / 120 VAC 220 / 230 / 240 VAC
RATED POWER 300W
SURGE POWER 400W
WAVEFORM True sine wave (THD < 6%)
FREQUENCY 50 / 60 Hz
OUTPUT
AC REGULATION A5%
POWER FACTOR ALLOWED COSq-90O ~ COSq+90O
STANDARD RECEPTACLES NEMA5-15R / GFCI Schuko / UK / Australia / universal
NO LOAD CURRENT DRAW 0.24A 0.28A 0.26A 0.28A
DC VOLTAGE 12VDC 24VDC 12VDC 24VDC
VOLTAGE RANGE 10.5~15.0VDC 21.0~30.0VDC 10.5~15.0VDC 21.0~30.0VDC
INPUT
EFFICIENCY (Typ.) 89.0% 89.0% 89.0% 89.0%
FUSE 40A x 1 25A x 1 40A x 1 25A x 1
REMOTE CONTROL By external switch
BAT. LOW SHUTDOWN 10 A0.5V 20 A1.0V 10 A0.5V 20 A1.0V
OVER LOAD Shut off output voltage, re-power on to recover
OVER VOLTAGE 15 ~ 16VDC 30 ~ 32VDC 15 ~ 16VDC 30 ~ 32VDC
PROTECTION
OVER TEMPERATURE Shut off output voltage, recovers automatically after temperature goes down
OUTPUT SHORT Shut off output voltage, re-power on to recover
BAT. POLARITY REVERSE By fuse open
WORKING TEMP. 0 ~ +40BC
ENVIRONMENT WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP. & HUMIDITY -30BC ~ +70BC / -22BF ~ +158BF / 10 ~ 95%
SAFETY STANDARDS UL458 (only for "GFCI" receptacles) -----
ISOLATION RESISTANCE I/P ~ O/P: 100M Ohms / 500VDC
EMI CONDUCTION & RADIATION Compliance to FCC class B Compliance to En55022 class B
SAFETY & EMC
EMS IMMUNITY ----- Compliance to EN61000-3 -2, 3
LVD ----- Compliance to EN60950-1
e-MARK ----- Compliance to e-13 * 72/245/EEC, 95/54/EC
DIMENSION 237 x 155 x 72mm (L x W x H)
PACKING 3.5kgs; 4sets / 17kgs / CARTON
OTHERS
COOLING Thermostatically controlled cooling fan
APPLICATION Home and Office appliances, Power tools and Portable equipments, Vehicle, Yacht and Solar power systems...etc.
Australia
NEMA 5-15R North America (GFCI) Universal Schuko New Zealand United Kingdom