Veterinary Infusion Pump
Bolus: 600ml/h
Flow rate range: 1-2000ml/h
Volume limit: 1-9999 ml...
Type: veterinary use

Veterinary Infusion/Syringe Pump Vet Infusion/SyringeBolus: 600ml/h
Flow rate range: 1-2000ml/h
Volume limit: 1-9999 ml...
Type: veterinary use

 

 

 

Veterinary Infusion Pump

 

Model AP-600IB

  Bolus: 600ml/h

  Flow rate range: 1-2000ml/h

  Volume limit: 1-9999 ml

  Accuracy: ±5

  KVO flow rate: 1ml/h, keep vein open(KVO) rate

  Power supply: AC100-240V, 50/60 Hz,25VA

  Max. power consumation:  25W,can run for more than 5 hours continously after fully recharged.

  Battery recharge: When the pump is working and connected to the AC power,the battery will automatically recharge (about 8-14 hours to recharge fully.)

  Displayed information: Flow rate,volume limit,accumulated volume,power indicator, bed No.,air,occlusion,empty.

  alarm function: Infusion completion,occlusion,air bubble,low battery,control abnormal,no AC power supply,installation error.

  Max. size of outer shell: 120×140×190 mmlength×width×height

  Max. weight: 2.5 kg

  Classification: Type BF


  Outer shell material:  ABS plastic

  Operating condition: Environment temperature +5- +40,atmosphere presure 86-106kPa,related humidity 20%-90%

  Storage and transport condition: Environment temperature -15- +50,atmosphere pressure 86-106kPa,relative humidity 20%-90%.

  Applicable infusion pipe: All standard infusion pipes.

  Work mode: Continuous work mode

  Applicable standard: Comply with standard of EN ISO 14971:2000, IEC 60601-1:1995,EN IEC 60601-1-2:2001, IEC 60601-2-24,EN ISO 14155-1:2003, EN 980:2003,EN 1041:1998, MDD 93/42 EEC

 

Technical Parameters of Infusion pump

Model

Veterinary infusion pump

 

Max.size of outer shell

120*140*190 mm(length*width*height)

Bolus

600ml/h

Alarm functions

Over,OCCL.,AIR,low battery, control abnormal, no AC power supply, installation error.

Flow rate range

1-600ml/h

Displayed information

Rate, volume limit, accumulated volume, power indicator light, bed No.,AIR,OCCL.,OVER.

Volume limit

1-9999ml

Max.weight

<2.0kg

Accuracy

±5%

Classification

Type II,BF

KVO flow rate

1ml/h,keep vein open(KV))rate

Outer shell material

ABS plastic

Max.power

consumption

 

25W,can run for more than 5 hours continuously after being fully recharged.

Operating conditions

Environment temperature +5°C~+40°C ,atmosphere pressure 86~106kPa, relative humidity20%~90%

Power supply

AC100-240V,50/60 Hz,25VA

Storage and transport conditions

Environment temperature -15 °C~+50°C ,atmosphere pressure 86~106kPa, relative humidity20%~90%.

Battery

Rechargeable lithium polymer battery,7.4V,1650mAh

Applicable infusion set

All standard infusion sets.

Certification

CE0197

EMC

Comply with EN60601-1-2

Work mode

Continuous work mode

Fuse

220V 2A*2,  12V 2A*2

Water proof

IP21

Electrical Shock Proof

Battery:Class II:AC Power:Type BF.

Battery recharge

When the pump is connected to the AC power supply, turn on the power and the battery will automatically recharge (about 8-14 hours to recharge fully).

Applied standards

Comply with standard of EN ISO 14971:2000,IEC 60601-1:1995,EN IEC  60601-1-2:2001,IEC 60601-2-24,EN ISO 14155-1:2003,EN 980:2003,EN 1041:1998,MDD 93/42EEC

 