1.Double CPU;
2.Accurate & sensitive pressure sensor detects occlusion pressure accurately;
3.Excellent injection operation.
Function & Features:
Model: Syringe Pump (SK-500II)
1. Three kinds of mode: Rate Mode, Time Mode, Body Weight Mode.
2. User-friendly, easy to operate, safe and convenient. English indicators, easy to identify.
3. Accept all standard syringes of 5ml, 10ml, 20ml, 30ml and 50ml.
4. Unique injection supervision system ensures the safe injection and reduces the nurse`s workload.
5. Excellent injection operation. The accuracy will be ensured even at small-volume injection.
6. Double CPU system makes the process of injection safer and more reliable.
7. Precision step motor. There is no pulsating wave even during low-rate injection.
8. Accurate and sensitive pressure sensor detects occlusion pressure accuracy.
9. Alarm is given when there is malfunction or operation error, and the machine stops running automatically.
10. KVO rate can be selectable according to concrete requirements from 0.1ml/h to 5ml/h.
11. Save the preset volume automatically when there is unpredictable switch off, ensuring the accuracy of injection volume.
12. Injection time, dose, solution can be checked during the process of injection.
Technical parameters:
Dimension: 288*130*122mm Weight: <3.0kg
Power supply: 50/60Hz AC100V~240V
Displayed information:
Flow rate; Accumulated injection volume; Volume limit; Syringe size; Pressure value; Syringe specification; Battery capacity; Unit of medical dosage; AC power indicator; Bed No.
Fuse: 220V2A*2, 12V2A*2
Maximum power consumption: 25VA, 5h after being recharged
Injection increment: 0.1ml
Accumulated injection volume: 0~9999.9ml
Injection accuracy: +/-3%
Alarm function ( All alarms can be transmitted to and displayed on the infusion supervision system at the nurse`s station ):
OVER / NEAR Occlusion; Low battery; Syringe disengaged; Syringe abnormal; Control abnormal; Internal malfunction.
Electrical safety: Complies with the stipulation of GB9706.1-1995, EN60601-1 and UL60601-1
Electromagnetic compatibility: Complies with the stipulation of IEC60601-1-2(1993 edition) EN60601-2-24
Applicable syringe: Syringes meeting national standard5ml, 10ml, 20ml, 30ml, 50ml
Feasible syringe rate range:
5ml syringe: 0.1~100ml/h 10ml syringe: 0.1~200ml/h
20ml syringe: 0.1~400ml/h 30ml syringe: 0.1~600ml/h
50ml syringe: 0.1~1500ml/h
Battery: Rechargeable lithium polymer battery, 7.4V, 1600mA
Bolus rate:
5ml: 100ml/h 10ml: 200ml/h
20ml: 400ml/h 30ml: 600ml/h
50ml: 1500ml/h
Occlusion value: 400mmHg~900mmHg
Selectable mode: Rate mode, Time mode, Body weight mode
Time Mode Volume limit: 0.1~999.9ml
Body Weight Mode: Selectable unit: Ml/h, mg/h, ug/h, mg/kg/h, mg/kg/min, ug/kg/h, ug/kg/min
Drug limit: 0.1~9999.9(mg/ug)
Solution limit: 0.1~999.9ml
Weight: 01~300.0kg
KVO rate: 0.1ml/~5.0ml/h(selectable)
Operating conditions: Environment temperature 5~45º C, air pressure 70~106kPa, relative humidity 30%~90%
Storage: Environment temperature -15~50º C, air pressure 70~106kPa, relative humidity 30%~90%