Welcome to B2BAGE
JT2DT-11 Water Temperature Meter of motorcycle parts
JT2DT-11 Water Temperature Meter of motorcycle parts

Minimum Order: 0
Quality/Safety Certification: 0.00


1.JT2DT-11 Water Temperature Meter of motorcycle parts
2.Working voltage:DC8-28V
3.High quality
4.Competitive price

Product name:          JT2DT-11 Water Temperature Meter

Technical Specifications: 1.Working voltage:DC8—28V

2.Temperature measurement range:0--120Degrees Celsius

3.Measurement error: ±1Degrees Celsius 

Installation and use of:

1. fixed the measurement table to the prople position of instrument sets,

and than installment the water temperature sensor plugs which matching the measurement table to the engine cooling Cean waterways (or replace the original car temperature sensor plugs). Finally, measure the table received a key to positive power line to control the power supply line, then car metal body negative.

2.Product wiring  diagram

 

 

3.when open the power,the measurement table start working,When the alarm sound at the same time temperature display “UU” or “00”, it means the temperature sensor plug that have open or short circuit fault line

4. After supply voltage display, under normal circumstances, should show the temperature sensor, temperature indicator light at the same time (time for the 50S), 50S after temperature display, but also show voltage 10S, while voltage indicator light, voltage, temperature, alternating display.

 5. Alarm function

When the water temperature more than 95Degrees Celsius less than 99Degrees Celsius, the measured surface temperature digital display will alternately show the actual temperature and “≡≡”, accompanied by beeps

When the temperature rose to 100 Degrees Celsius, the measurement of surface temperature display shows "00" and 30 accompanied by beeps

6. Fan control

(For cooling equipment with electronic control model) when the engine temperature reaches 85 Degrees Celsius, the measurement of surface temperature display shows "85" At the same cooling fan indicator light, instrument automatically switches cooling equipment (such as water spray, cooling fan) control following the electrical appliances, (using the cooling function must take relay) to reach the objective of automatic cooling (negative effective).

When the temperature dropped to 75 Degrees Celsius, the measurement of surface temperature display shows "75" At the same cooling fan light is off, control the cooling fan relay not working (no signal output), stop cooling the engine at constant temperature state.

7. Voltage alarm

When working voltage less than 9V, 21V, or higher than 16V, 28V, the instrument will alarm

Notes:

1. Installation, meter connection as far as possible away from interference sources, such as speakers, power lines, so as not to affect the instrument to work

2. Mounting bracket with ordinary flashlight can stand (provided)

3. Connection with the corresponding color, position, when use 8mm sensing, the installation should not force too much, so as not to wring

4. Installation location must not be the sun and light, rain

Ads by Google