Analogue Oscilloscope,V-5040D, three channel/six trace
Analogue Oscilloscope,V-5040D, three channel/six trace

Minimum Order: 0
Quality/Safety Certification: 0.00


CRT digital cursor readout, HOLD OFF function
CH1 input, maximum 400V input voltage
Scan speed up to 5ns/division

Specifications
 
DescriptionModel: V-5040D  40MHz  digital readout oscilloscope
Division line6" screen with internal division lines: 8x10 divisions(1 division=1CM)
Phosphor powderP31 standard
Accelerating voltage12KV
Vertical deflection system
SensitivityCH1 or CH2:
2mV/division to 5V/division +/-3% (for 11 ranges), continuously adjustable
CH3: 0.1V/division
FrequencyDC-40MHz
Rise time5.9ns
Delay timeFront edge can be observed
Max. Input voltage400V (DC+AC peak value) when≤1KHz
Input couplingCH1, CH2,
AC, DC grounding
CH3, AC, DC
Display modeCH1, CH2, CH3, superposition, alternation, intermittent
Polar selection+/-(only CH2)
X-Y operationX axle and Y axle selection
SensitivityX axle: CH1, CH2 2mV to 5V/division +/-5%
           CH3: 0.1V/division +/-5%
Y axle: 2mV to 5V/division +/-3%
Phase difference≤3º, DC-50KHz
Bandwidth of X axleDC-500KHz (-3dB)
Horizontal reflection system
Triggering modeNORM mode, AUTO mode
Scan modeMain scan, continuous delayed scan
Triggering sourceCH1, CH2, VERT, EXT
TV triggerExternal synchronous separation circuit
Trigger level 
AUTO NORM
Adjustable range
Automatically synchronized to trigger signal
+/-4 divisions
Slope+/-
Scan timeA: 50ns/division to 5s/division
B: 50ns/division to 50s/division
Accuracyx1:   10ºC to 35ºC  +/-3% ;    0ºC to 50ºC  +/-4%
x10: 10ºC to 35ºC  +/-4% ;    0ºC to 50ºC  +/-6%
Scan expansion widthx10
Maximum scan50ns
HOLD OFF timeAdjustable
Delay time1us to 5s
Readout timeVertical axle: V/DIV, UNCAL, probe factor
Scan speed: S/DIV, UNCAL, MAG
Cursor readout functionΔV, ΔT, Δ1/T
Correction waveformFrequency: 1KHz  20%
Voltage:      0.5V  1%
Power supply220V/110V +/-10%;  50/60Hz
Dimensions310(W) x 130(H) x 370(D)mm
Weight9kg
Environmental
Temperature
During operation: 0ºC to 40ºC
Safe operation temperature: 10ºC to 35ºC
Storage temperature: -20ºC to 70ºC
HumidityMeasurement: 35-85%RH
Storage: 45-85%RH
Specifications subject to change for product improvement without prior notice.

 