CK200206 double-deck bus HVAC control panel
Minimum Order: 0
Quality/Safety Certification: 0.00
CK200206 double-deck bus HVAC control panel
1.For double-decker bus
2.Power consumption:4.5W
3.YUTONG bus
CK200206 double bus HVAC control panel apply to double-deck bus climate control.
Function: fully-automatic control, cooling, fresh air, memory, independent temp, set of double decks, error alarm, shift function, input voltagedetecting.
Shift function:
1)Running time check (press fan button no less than 3S )
2)Defrost temp. display (press fresh air button no less than 3S)
3)Hold cool (press cool button no less than 3S)
Technical data:
Technical date | CK200206 | |
Power supply | DC24V(DC20V-DC32V) | |
Power consumption | 4.5W | |
Current | Max.200mA | |
Dimensions | 168X66X54 | |
Display | LED (true color/red) | |
Ambient temperature | -30°c —80°c 5%-95%RH Non-condensing | |
Storage temperature | -10°c—70°c 5%-95%RH Non-condensing | |
Display precision | Dual digit display of set temp., accuracy 1°c; dual digit display of inside temp. accuracy 1°c | |
| Temp. control based on the temp. of return air inlet, the defrost sensor controls defrost temp., defrost on at 2°c, defrost off at 7°c | |
Connector | Plug HP5557-22R | |
Faceplate level | IP54 | |
EMC level | EN50081&EN50082-2 | |
Security level | Applied to EN61010-II, Pollution degree: II | |
Weight | 360g |
Input | 1) Inside temp. sensor 1 (25°c,Rb=5K,B=3274) |
2) Defrost sensor (25°c,Rb=5K,B=3274) | |
3) Pressure switch | |
4) ACC(battery) | |
5) Backup lamp power | |
Output | 1) Condenser fan(max.1A) |
2) Fan high (max.1A) | |
3) Fan mid (max.1A) | |
4) Fan low (max.1A) | |
5) Fresh air open (max.1A) | |
6) Fresh air close (max.1A) | |
7) Compressor clutch (max.1A) |