Welcome to B2BAGE
IFS 258 Automatic burner control units/Control box
IFS 258 Automatic burner control units/Control box

Minimum Order: 0
Quality/Safety Certification: 0.00


Flame control with ionisation sensor
or UV sensor
Ignition and monitoring with a single
electrode

  

 

  The automatic burner control units ignite and monitor gas burners in intermittent operation, i.e. the burners must be shut down once in every 24 hours. They are used in directly ignited gas burners of any capacity (ignition power ≤ 350 kW) in which, for technical reasons, pre-purging is omitted or controlled by a separate control system. Typical areas of application are industrial thermal process systems to EN 746 in the iron, steel, glass, ceramics, plastics processing and chemical industries. In addition, the IFS 258 are also suitable for use with atmospheric burners in other heatgenerating systems. The units are type-tested and certified in accordance with EC Directive 90/396/EEC for gas appliances in conjunction with EN 298.

 Main modles as follow:

 

 

 

ModelIFS 258-3/1W IFS 258-5/1W IFS 258-10/1W
Code TC100001 TC100002 TC100003

Minimum switch-on time for the J signal:

8s 10s 15s 

 

 

 Mains voltage:

  230 V AC, -15/+10%, 50 Hz, for earthed and non-earthed systems.

 Power consumption: Approx. 19 VA (7W).Output voltage for valve and ignition transformer = Mains voltage.
 Output current:

  Max. 2 A per output, total current max. 2.5 A.

 Fuse in unit:

  3.15 A, slow-blow H, to IEC 127-2/5.

 Flame control:

  Ionisation sensor or UV sensor.

 Sensor voltage or voltage at UV sensor: Approx. 230 V AC.
 with UV control: Max. 100 m
 Average number of operating cycles as a function of power factor cos j: Approx. 1 x 106, with single-electrode operation:270000
 Valve connections: 1
 Ambient temperature:

 -20°C to +60°C, no moisture condensation admissible.

 Enclosure: IP40 to IEC 529
 in the area of the measuring sockets: IP30
 Construction:

  Housing made of impact and heat-resistant plastic, plug-in upper section with operating controls and indicators.Bottom section (Fig. 15) with connection terminals, earth and pre-wired neutral bus with generous cable space.

 Weight: 0.51kg

 

 

 

 

 

 