Welcome to B2BAGE
Triphase 5kw-8kw electromagnetism inductance heating up controller for injection molding machine
Triphase 5kw-8kw electromagnetism inductance heating up controller for injection molding machine

Minimum Order: 0
Quality/Safety Certification: 0.00


Triphase 5kw-8kw electromagnetism inductance heating up controller for injection molding machine
1,Rated voltage: AC 380V/50Hz

Triphase 5kw-8kw the specification of the electromagnetism inductance heating up controller

 

A. The specification of the product electric

1,  Rated voltage: AC 380V/50HZ

2,  Scope of application: 310V~430V

3,  Rated Power: 5kw-8KW

 

B. The ability to adapting the surroundings

1,  Temperature: -20°C~50°C

2,  Humidity ≤95%

 

C. General introduction of basic functions

1, The feature of electricity and voltage: Constant current output

2, Thermal efficiency: ≥90%

3, IGBT heat preservation: 95±5°C

4, Work frequency: 16-30KHZ

5, Half-bridge series resonant converter

6, With Soft-start heating/Stop model

7, With protection function of heating loops

8, With one detection interface of 10’s place precision, the detection scope is 0-150°C

9, With many loops superposition of 100KW and work without no interfaces

10,      The sizes are: Length 220mm * Width 200mm * height 110mm (the radiating fan 380V150mm should be installed separately and it was matched)

11,      The average working hour is above 10000 hours

 

D. The explanation and sketch of the system

1,A light: Normal working hours, long bright light; No load or do not work, the indicator light 0.5S, 0.5S off cycle

2,JieShou This terminal is used to start or stop. the work when in open; When closed, is to stop the (also can be set to when the road is closed when the work, when the open circuit is stopped) Users can not use it. To stop it, disconnect its total power supply.

3,RW This terminal is used to adjust the power connection.

4,A, B, C is the three-phase three-wire power input.

5,OUT1 and OUT2 are connected to the heating coil.

6,Coil reference parameters: mica wrapped glass fiber woven high temperature cable.

8KW cross section 10mm2 inductance is 180-250uH, about on-line around the barrel length of 33 meters, cotton insulation thickness of about 12-15mm.

7,Debugging method is simple: work as per normal phase current is about 10-10.5A, showing the normal operating frequency for the 17-20K or so, if the high frequency to a necessity to increase the coil, and vice versa to reduce the coil. After debugging. Unplug the monitor.