Fluke 725
Measure and source mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure
input/output value

· 

The Fluke 725 Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator. Use the measure and source functions to test and calibrate almost any process parameter.Small, streamlined shape makes it easy to carry

· Rugged, reliable design stands up to field use

· Easy to read measure/source screen lets you view input and output simultaneously

· Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters

· Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters

· Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules

· Source mA with simultaneous pressure measurement to conduct valve and I/P tests

· Support flow meter testing with frequency and CPM functions

 

· Perform fast linearity tests with auto- step and auto-ramp features

· Power transmitters during test using loop supply with simultaneous mA measurement

· Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms

· Store frequently used test setups for later use

· Backlight lets you work in poor light

· Large battery capacity of four AA cells

· Battery door for easy changes

 

Measurement Accuracy

Voltage DC

30.000 V

 0.02%+ 2 counts (upper display)

30.000 V

 0.02%+ 2 counts (lower display)

100.00 mV

 0.02%+ 2 counts

-10.00 mV to 75.00 mV

 0.025 % + 1 count (via TC connector)

 

Current DC

24.000 mA

 0.02%+ 2 counts

 

Resistance

0.0 to 400.0 Ω

 0.1Ω (4-wire), 0.15Ω (2- and 3-wire)

401 to 1500 Ω

 0.5Ω (4-wire), 1Ω (2- and 3-wire)

1500 to 3200 Ω

 1Ω (4-wire), 1.5Ω (2- and 3-wire)

 

Frequency

2.0 to 1000.0 CPM

 0.05 % + 1 count

1.0 to 1100.0 Hz

 0.05 % + 1 count

1.00 to 10.00 kHz

 0.05 % + 1 count

Sensitivity

 1 V peak-to-peak-minimum

 

Pressure

Accuracy

 from 0.025% of range using any of 29 pressure modules.

 

 (for detailed specifications refer to pressure modules in options and accessories)

 

 Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

 

Source Accuracy

Voltage DC

100.00 mV

 0.02%+2 counts

10.000 V

 0.02%+2 counts

-10.00 mV to 75.00 mV

 0.025 % + 1 count (via TC connector)

 

 

 