Gas detector-four in one
Applicable to multi gas detection
For HAZMAT response and aftergases detection
ISO9001 certificate
Gas detector – four in one multiple gas detector
Features
• Fully functional self-testing: sensor, integrity of battery and circuit, acoustic & visual & vibration three-stage alarm.
• Real-time detection for the concentration of hydrogen sulfide (H2S), carbon monoxide (CO), sulfur dioxide (SO2), oxygen (O2) and combustible gas.
• Gas Alert Micro series have a wide application, including HAZMAT response, enclosure space entry and post fire inspection.
• The deadline date and alarm threshold can be adjusted based on the request in special industry.
• Password protection capability: only the authorized user can modify the preset parameter.
• It is the primary inspection tool with high performance-price ratio and multiple functions in the field of multiple gas detecting.
• TWA (time weighted average) alarm and STEL (short-term exposure limit) alarm is applicable to H2S and CO; OL (over limit) alarm is applicable to combustible gas.
• Keep record of TWA, STEL and peak value of gas composition for display when needed.
Technical Specifications
Dimensions | 100mm*60mm*33mm |
Weight | 211g |
Operating & Storage Environment | Temperature: -20°C~50°C (-4F~122F) Humidity: 5%-95% Relative Humidity Pressure: 95~110kPa |
Alarm Threshold (Two-stage) | There may be regional variations, users can set up the value based on the practical situation. |
Detecting Range | CO: 0~500 PPM H2S / SO2:0~100 PPM O2: 0~30% (steadily increasing with increment of 0.1%) Combustible Gas: Can be set up based on user’s need (0~100%LEL or 0~5.0% v/v methane) |
Transducer | H2S / CO: two in one plug-in electrochemical battery O2 / SO2 / H2S / CO: single plug-in electrochemical battery Combustible gas: plug-in catalytic combustion transducer Oxygen detection principle: capillary controlling concentration transducer |
Alarm Type | TWA alarm, STEL alarm, low & high alarm, multiple gas alarm, sensor alarm, battery low alarm, prompt tone, automatic shutdown alarm |
Acoustic Alarm | Variable-frequency pulse alarm which can reach volume of 95dB in a distance of 1 foot (0.3 meters) |
Visual Alarm | Two red LBD omnibearing visible glitter alarm |
Vibration Alarm | Pulsant signals alert the gas alarm or any other alarm status |
Display | Alphanumeric LCD displays the real time gas concentration and alarm stage |
Backlight | Automatically activated when working in poor lighting environment or the alarm sounding. |
Self-checking Function | Self-checking after start up. |
Calibration Function | Automatic zero point calibration / Automatic measurement range calibration |
Continuous working period | 2*alkaline battery: 16~18 hours 2* nickel-hydrogen rechargeable battery: 14~16 hours |
Initial Charging Duration | 1~4 hours for each battery |
Normal Charging Duration | 1 hour for each battery |
Attentions
• The transducers have high resistance to common steam and gas.
• The transducers will start self-cleaning if move the detector to clean environment and wait for 10~30 min.
• Be sure not to expose the transducer to inorganic solvent steam (such as paint gas) and organic solvent.
• Do not test the response of combustible gas transducer by a liquid cigarette lighter, or the transducer will be damaged.
• Please set the detector when first applied, the next adjustment can be confirmed based on the exposure duration of transducer in the toxic gas (recommended frequency is semiyearly).
Ordering Information
GAMIC-4 GasAlertMicro gas detector: for hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gas.
GAMIC-3 GasAlertMicro gas detector: for hydrogen sulfide (H2S), oxygen (O2) and combustible gas.
GAMIC-2 GasAlertMicro gas detector: for oxygen (O2) and combustible gas.
Gas Type | H2S | CO | O2 | Combustible Gas |
Detecting Range | 0~100 PPM | 0~500 PPM | 0~30.0%VOL | 0~100%LEL |
Low Alarm Point | 10 PPM | 35 PPM | 19.5%VOL | 10%LEL |
TWA Alarm Point | 10 PPM | 35 PPM | Not applicable | Not applicable |