1)wind controller also can make wind solar hybird controller
2)Perfect protection, high stability
3)high power,energy saving
wind controller,wind solar hybird controller specification:
Wind turbine controller
Tanfon TCW series controller is intelligent model for wind turbine controller, with PWM charging mode and electronic brake function.
It can design for the capacity of the current according to customer’s need. Through the use of microcomputer chips, it can achieve the controll of wind generator operation, rectification and charging ,and protection effect.
Features
l,Completely CPU control
2,Rectification: to rectify AC power from wind turbine to stable DC power ,feed to battery bank
3,PWM constant voltage charging protects the storage batteries, make full use of the energy
4,Over-charge and over-discharge, reverse connection, electronics brake protection
5. Protect the generator and blades, it will yaw at a 90 degrees from the wind direction when the wind speed is higher than security wind speed
6.Wind and Electricity hybrid function: have electricity charge function ,when the wind speed is low ,can charge the power from electricity to battery bank.
Specifications
Model | TCW-200 | TCW-300 | TCW-500 | TCW-1K | TCW-2K |
Rated Power | 200W | 300W | 500W | 1000W | 2000W |
Rated DC Voltage | 24V | 24V | 24V | 48V | 48V |
Over-discharge protection voltage | 21V | 21V | 21V | 42V | 42V |
Over-discharge recovery voltage | 23.5V | 23.5V | 23.5V | 47V | 47V |
Over-charged protection voltage | 30V | 30V | 30V | 60V | 60V |
Over-charged recovery voltage | 29V | 29V | 29V | 58V | 58V |
Regulative voltage | 28V | 28V | 28V | 56V | 56V |
Max. charge current | 10A | 14A | 23A | 25A | 40A |
Unload current | ≤100 mA | ||||
Cooling type | Auto cooling & fan | ||||
Protection | Over-charge, over-discharge, unloading, manual and electronic braking, etc. |
Model | TCW3K | TCW5K | TCW10K | TCW20K | TCW50K |
Rated Power | 3KW | 5KW | 10KW | 20KW | 50KW |
Rated DC Voltage | 96V | 120V | 240V | 360V | 690V |
Over-discharge protection voltage | 84V | 105V | 210V | 315V | 605V |
Over-discharge recovery voltage | 94V | 118V | 235V | 352.5V | 676V |
Over-charged protection voltage | 120V | 150V | 300V | 450V | 862V |
Over-charged recovery voltage | 117V | 145V | 290V | 435V | 841V |
Regulative voltage | 113V | 140V | 280V | 420V | 811V |
Max. charge current | 31A | 41A | 41A | 56A | 72A |
Unload current | ≤500 mA | ||||
Cooling type | Auto cooling & fan | ||||
Protection | Over-charge, over-discharge, unloading, manual and electronic braking, etc |