1,We supply air aftercooler
2,With ISO9001-2000 certification
3,High quality with long life time,few maintainance
SSCE-AC-12 Aftercooler
Compressed air is hot and saturated with moisture upon leaving the air-compressor. Moisture in the compressed air-supply will corrode working parts, shortening their life span and resulting in repair and replacement down time.
FUNCTIONS
Water-cooled after-coolers perform two essential functions. They rapidly reduce temperature of the discharged air from the compressor to a safe operating range. Substantial amount of the entrained moisture will be removed.
FEATURES
The unique system whereby water passes through the copper-nickel tubing and air-flows in the opposite direction through baffled plate inside the hot galvanized shell casing ensures trouble free operation of after-coolers. Each after-cooler is furnished with correct number square inches of zinc anode to minimize galvanic corrosion.
The after-coolers are fitted with an efficient centrifugal moisture separator that comes with 75 micron filter.
We designs after-cooler of different capacities to meet clients’ specific requirement. We can also offer air-cooled after-cooler, which are wither driven by electric motor (explosion proof) or compressed air.
Model No: | SSCE-AC-12 |
Air Capacity: | 4200cfm |
Air Inlet Temperature: | 80 deg.C |
Air Outlet Temperature: | 38 deg.C |
Entering Cooling water: | 28 deg.C |
Cooling water quantity: | 180gpm |
Safe Working Pressure: | 10bar (air)/10bar (cooling water) |
Dimension: | 2.7 x 0.9 x 1.9m (H) |
Weight: | 1050kg |
Inlet Manifold: | 6 ports x 2" c/w ball-valves |
Outlet Manifold: | 12 ports x 1-1/4" ball-valves and 4 ports x 1" c/w ball-valves |
Standard Accessories: | Pressure Gauge, Safety relief valve, Temperature gauge, Moisture-separator with drain valve, Inlet-water filter and Drain hose (50ft) |