Welcome to B2BAGE
displacer level meter
displacer level meter

Minimum Order: 0
Quality/Safety Certification: 0.00


displacemer level meter adopts stress measuring method by applying the lever principle.

displacemer level meter adopts stress measuring method by applying the lever principle to acquires the signal being consistent with fluid level change and being measured through high precision spectacles cantilever stress sensor. Via being processed by A/D converter, MPU and D/A converter, the measured signal is transferred into 4-20mA analog signal and digital signal that is conformity with HART PROTOCOL and is superimposed on the analog signal, and then the processed signal is output. It is provided with the function of highly accuracy for linearity treatment, strong interfere- resistance, remote configuration, checking, maintenance and adjustment. This meter can work together with equipment being conformity with HART protocol in the field bus so as to realize the digital two-way communication, process checking and automatic controlling. It also is compatible with analog meter. It features pretty external appearance as its fashionable shell structure design. This structure makes each chamber separately to make the meter more reliable and safe. Also the meter is added a   precise static pressure adjustment device so as to keep high precision and reliability. Both shell structure design and the static pressure adjustment device have been granted the national patents. 

The patent number for external appearance design: 99 3 21507.6

The patent number for static pressure adjustment device: 99 2 23728.9

Performances

LCD display: field display related variables

Local and remote configuration function: through the magnetic switch in the transmitters  head, or a handle communicator or a computer with commissioning software to read and write and configure all kinds of process variables, the signal (4~20mA)on which every parameter and variables being conformity with HART protocol

Self-diagnosis function: alarm when the fluid level exceeds the range and various failures occur

Shock resistance, electromagnetic interference resistance; 

Zero point and full scale adjustments, no interference between the two kinds of adjustment

Protection grade: IP65

Flange standard: JB/T82.1-94; JB/T82.2-94. (please note if other standard being adopted)

Qualifications

Operating voltage: DC24V

Input impedance: > 100MΩ

Load Resistance:  ≤600MΩ

Nominal Pressure:  2.5, 4.0, 6.4MPa

Precision:  0.5% FS,  1.0% FS

Operating Temperature: ≤100.C (without radiating fin) , ≤400.C (with radiating fin)

Damping Period: 0~199 second

Power supply inlet: M20×1.5.

Explosion-proof and Guard Grating

Explosion-proof type

Intrinsically safe explosion-proof

Explosion-proof sign

ia IICT5

Explosion-proof certificate number

CYB 99270

 

 

Qualified and Compatible Guard Grating

Qualified and Compatible Guard Grating

Shanghai Intrinsic Explosion-proof instrument System  Co. Ltd

LS4041-EX

Shanghai Automation Instrument Research Institute

GS8041-EX

Longfei Group Corporation

LF1045

Britain

MTL3046B  MTL5042  MTL706+

Germany P+F

KFD2-STC3-EX1

Dandong Top Electronic Instruments Co., Ltd

TP5041 – Ex  TP5045 - Ex

Measuring Range and Medium Density 

Measuring Category

Measuring Range (mm)

 Medium Density

Liquid  Level

300,500,600,800,
1500,2000,2500

 0.3~1.6g/cm3

Interface Level

500,600,800,1000

Density Difference ≥0.1g/cm3

1500,2000,2500

Density Difference ≥0.2g/cm3

Density

Same as the interface level measuring range 

Density Difference  ≥0.1g/cm3