Minimum Order: 0
Quality/Safety Certification: 0.00


Specifications
1. Pass: ISO9001 certification.
2. Fine after-sale services.
3. Small order accepted.
4. Samples available

Fe-CuNi thermocouple (type J) is also named Fe- Constantan thermocouple. The positive leg Fe(JP) is made by pure Iron, and the main chemical composition of negative leg Constantan (JN) is Cu: Ni≈ 55%: 45%. Although they are all called Constantan, JN does not give the same EMF output curve as EN and TN, it cannot be instead by other Constantan.

The operating temperature range of type J thermocouple is -210~1200°C, but it is usually used in the temperature range 0~750°C due to embrittlement of Iron.

Type J thermocouple has good resistance to oxidation and high EMF output against Platinum 67, with good temperature accuracy, sensitivity and stability. It is recommended for vacuum, oxidizing, reducing or inert atmospheres, but it can not be used in sulphurous atmosphere above 500°C. 

Fe-CuNi thermocouple (type J) is also named Fe- Constantan thermocouple. The positive leg Fe(JP) is made by pure Iron, and the main chemical composition of negative leg Constantan (JN) is Cu: Ni≈ 55%: 45%. Although they are all called Constantan, JN does not give the same EMF output curve as EN and TN, it cannot be instead by other Constantan.

The operating temperature range of type J thermocouple is -210~1200°C, but it is usually used in the temperature range 0~750°C due to embrittlement of Iron.

Type J thermocouple has good resistance to oxidation and high EMF output against Platinum 67, with good temperature accuracy, sensitivity and stability. It is recommended for vacuum, oxidizing, reducing or inert atmospheres, but it can not be used in sulphurous atmosphere above 500°C.

 

Calibration Type Characteristics

Type

Singles

Normal Operating Temperatures (°F)

J

Iron (JP)/ Constantan(JN)

200-1500

K

ChromelP(KP)/Alumel(KN)

200-2000

T

Copper(TP)/ Constantan(TN)

200-600

E

ChromelP(EP)/ Constantan(EN)

200-1600


TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres. Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures.

TYPE K (CHROMEL vs ALUMEL ) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures.

TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum. It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures. It is the only type with limits of error guaranteed for cryogenic temperatures.

TYPE E (CHROMEL vs Constantan) may be used in oxidizing, inert or dry reducing atmospheres, or for short periods of time under vacuum. Must be protected from sulfurous and marginally oxidizingatmospheres. Produces the highest EMF per degree o any standardized thermocouple.

 

 