Welcome to B2BAGE
electric power inverter 16 ports
electric power inverter 16 ports

Minimum Order: 0
Quality/Safety Certification: 0.00


electric power inverter
1.Approval:CE,FCC,ISO9001
2.Maximumt:300W
3.output:13.8W.
4.each:-48VDC/350MA

electric power inverter

Features and functions

poe PROCET PT- PSE1601 is a sixteen ports concentrated network long-distance power supply implement. It is suitable for indoor, can work regularly between input voltage 100VAC ~ 280VAC.This power supply use super type 5 cable to connect with network terminal equipment, suitable for 10/100M network environment.
PROCET PT- PSE1601 concentrated power supply implement has the excellent performance as below

1 The power circuit has the function of Input over or under voltage, output over voltage, output over-current short-circuit protection for each circuit.

2 System reliabilityMTBF 100k hours.

3Conducted interference(CE) Radiated interference(RE),comply with EN55022, CLASS B standard.

4 Lightning protection: Both positive and negative port of AC input can take 5KB, 8/20uS pulse current for 5 times, with interval of 1 minute. Power supply lightning protection circuit has the failure alarm function and safety protection devices like insurance tube etc.

5  Cooling way  Air-cooled

6 Sound of noise  50Db

7 5 seconds after starting up a computer, normally output.

Operating Environment

1.Temperature  -5°C~+55°C

2.Relative humidity 5%~90%RH

3.Places that are ventilate and cool, clean, no conductive dust, no corrosive gases.

4.Places without explosion hazard.

Technical characteristics and parameters

Input voltage:100VAC~280VAC,47Hz~63Hz.

Maximum power output:300W. One way power output:13.8W.

Total power output has 16 circuits , each output voltage/current:-48VDC/350MA

Output voltage regulation accuracy:-48VDC±2%.

Load regulation:-48VDC±1%.

Operating temperature range:-5°C~+55°C.

DC output noise voltage: broadband noise voltage.

3.4kHz~150kHz≤50mv 0.15MHz~30MHz≤20mv

Discrete noise voltage

3.4KHz~150KHz≤5mv
150KHz~200KHz≤3mv
200KHz~500KHz≤2mv
0.5MHz~30MHz≤1mv

Remote Power Supply Protection

Range of output over-voltage protection:-52VDC~-50VDC

Over-current protection(Single circuit):350Ma~400Ma

Over voltage protection:Input voltage over 290VAC~310VAC

Over voltage recovery point:Input voltage over 285VAC

Under voltage protection:Input voltage under 85VAC~90VAC

Under voltage recovery point:Input voltage under 100VAC

Over-temperature protection:Over 100°C

 

Ethernet ports light instructions
Red light POWER on Show power working normally
Green light ACTIVE on  show equipment supply power normally

Green light in network port is on and then off after several seconds show overload protection or short circuit.

Red light shining slightly in use shows feed part of the network port is off-loads, can judge there is a glitch of the power supply or far-end equipment.

Installation and Commissioning.
1. Insert the input power line into 100--220VAC introducing input socket.

2. Connected to the output signal respectively
3. Connect communicating & introducing line, signal wire, output lines tightly to avoid bad contacts and loose.

Note
Item 1:The installation site must be away from heat source and electromagnetism interference source, non-corrosive gas and metal dust.
Item 2:Mustn’t block the cooling hole of the equipment.

Item 3:Installation must be stable fixed placing, not a violent shock.
Item 4:Note whether the AC input voltage is during the range of 100VAC ~ 280VAC.
Item 5:Prevent to crash and conflict with other equipment during the installation, so as not to cause local damage of the machine surface.

Boot Test

1.Using resistance gears of millimeter to detect Ac input, short circuit phenomena did not exit; after loading, green light in output interface is on shows output normally. If it is off after several seconds shows short circuit and limited flow phenomena did exit.
2. After electric communication, the working light in front board is on.

Daily maintenance and maintenance:

Long-distance power supply poe  PROCET PT- PSE1601 can work uninterruptedly,to guarantee the reliability of the power supply, must prepare daily maintenance work, make the power system in the best working state.
1. Clean power source regularly to prevent dirt retention phenomenon

2. Check whether the connecting line of input and output is loose or contact undesirable, if damaged, please change in time.

Transportation

In handling process please handle with care, do not make it strong impact.It should be placed strictly according to the direction of instructions in packing during transportation or may cause glitch or damage.

Storage
When storing, must be kept in dry warehouse, not exposure to sun and rain.
Storage temperature: -5°C~+55°C (low temperature storage recovery time is at least 4 hours)
Relative humidity: 5% ~90%RH 