1)Shell : PC + ABS engineering plastics
2)Installation : DIN rail
3)Dimensions:110*60*100 mm (L*W*H)
TLD-500 is used for wherever vehicles have to be detected, for example for monitoring and safe-guarding accessways or for counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems or activating card dispensers in parking lots. It uses the advanced microprocessor technology, and can work in diverse environments. TLD-500 has two-way output relays. One is unlimited output when loop is temporarily covered, while the other is multi-mode that can be set by users.
Specification:
Operating voltages 220V AC±10%
Power consumption 5W
Output Relay output
Frequency range 20kHz to 170kHz (4 grades adjustable)
Reaction time 20 ms
Sensitivity 10 grades adjustable
Loop inductance: Ideal 100300µH (include connecting wiring)
Max 50µH1000µH (include connecting wiring)
Loop conn. Wiring: max. 100m, twisted at least 20 times per meter, total resistance <10 Ohm
Operating temp.: -30 to +75
Storage temp.: -40 to +85
Relative humidity: ≤ 95%
Connection: 11-pin socket
Shell : PC + ABS engineering plastics
Installation : DIN rail
Dimensions: 110×60×100 mm (L×W×H)
Net Weight: 400g (include socket)