Welcome to B2BAGE
solar cell tester
solar cell tester

Minimum Order: 0
Quality/Safety Certification: 0.00


1- Project planning
2- supply of complete production line
3- Installation
4- Trial production
5- After sales service

Specifications

1,Equipment Specifications

1.1,Simulated light source

a,High-power pulsed xenon lamp.

b,Spectral range is AM1.5 which meet the IEC60904-9 requirements  of spectral                                                                  irradiance distribution.    

c,Light intensity 100mW/cm2(Adjustment range 20~120mW/cm2).

d,Irradiation uniformity  ±2%  .            

e,Irradiation instability   ≤±2%          

f,Xenon lamp life time  300,000(German imports)

g,Counting the number of features with Flash(Replacement of zero reset)

h,The light under the direction of the vertical lighting.

1.2,Test range

a,Effective test area--200mm×200mm

b,Effective test range--0.1W~5W

c,Measuring voltage--0V~0.8V(Resolution 1mV)   

d,Measuring current-- 0 mA~20A(Resolution 1mA)   

e,Temperature measurement--15°C~35°C(Resolution 0.1°C)

1.3,Test Accuracy

a,Test repeatability accuracy--±0.5%

b,Measurement error--≤2%

1.4,Measurements--Four-wire measurement

1.5,Test parameters--Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp ,Rs,Rsh.

1.6,Test interval--3 seconds / piece

1.7,Data Acquisition--I-V curve with 5000 data collection points

1.8,Calibration test conditions--Self-correction device(Including manually enter the compensation parameters, automatic / manual temperature compensation, automatic compensation of light intensity)

1.9,Temperature measurement

a,Automatic test temperature

b,Temperature compensation and display.

1.10,Test results

a,Test timeand graphical display parameters(I-V characteristic curve).

b,Test results have converted to the standard test conditions

c,Voice reported that the number of test results and voice prompts

1.11,Test report

a,Interface and can record the current work shows IV curves

b,All components can be a major test parameters specified file saved to your hard disk

c,The specified file name can be self

1.12,Data collection and printing

a,Set time period or at any time according to the data summarized.

b,In Excel format printing(Including the cumulative output IV curve).

1.13,Special software

a,Temperature compensation coefficient input.

b,Date Name of the ranks of the number of input.

c,Start to set auto-increment sequence number.

d,Bad product range of parameters set.

e,In English and in Chinese and English interface to switch the contents of print.

 

  

Ads by Google



About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.