Welcome to B2BAGE
FZW32-40.5 outdoor AC high voltage vacuum load break switch
FZW32-40.5 outdoor AC high voltage vacuum load break switch

Minimum Order: 0
Quality/Safety Certification: 0.00


FZW32-40.5 outdoor AC high voltage vacuum load break switch
1.high voltage
2.Provide OEM service
3.VCB
4.ISO9001:2008 CE

FZW32-40.5 outdoor AC high voltage vacuum load break switch

1.high voltage
2.Provide OEM service
3.VCB
4.ISO9001:2008 CE RoHS
FZW32-40.5/T1250-25 outdoor high voltage isolate vacuum switch is a new generation of high voltage electrical equipment developed by both home and overseas advanced technology. Each of the technical performance have reach the standard of GB3804 and IEC.

They are designed for the construction and reform of urban and rural grid. The bottom of the product has adopted stainless steel and galvanized carbon steel with ultraviolet-proof coating material, to make sure it’s normal outdoor operation. Each stainless steel component can ensure it’s durability, stability, water-proof and salt fog against ability.

It has characteristic of small size, light weight, good appearance, easy operation, strong breaking ability, long electrical life maintenance free and obvious fracture. It can adopt manual single-pole operation and also electric, distance operation.

Ambient condition

1 Ambient temperature: max +40°C min -40°C

2 Altitude: ≤2000m

3 Wind pressure: ≤700Pa(equals to wind speed 34m/s)

4 Relative humidity: daily average relative humidity: ≤95%; monthly average relative humidity≤90%

5 Air contamination degree: IV degree

6 Earthquake intensity: ≤8 degree, no frequent violent vibration.

Order instruction

Complete model and order quantity of the product

Rated current, rated voltage

Manual or electric operation

Installation method

Required accessory and quantity

Other requirement please contact with us directly

Main Technical Data    
Rated voltage                                                             kv40.5
Rated current                                                             A1250
Rated frequenceHz50
Rated breaking current of active load A1250
Rated breaking current of close loopA1250
5% rated breaking current of active loadkA62.5
Rated cable charging breaking currentkA25
Rated lighting impulse withstand voltagekvInterphase or to ground 185,fructure 215
Rated short-time power frequency withstand voltage(1 min)   kvInterphase or to ground 95,fructure 110
Rated short time withstand current (thermostability)kA25
Rated duration of short-circuit                              s4
Rated peak withstand current (dynamic stability)kA63
Rated short-circuit making current    kA63
Mechanical life                                           times10000
Contact erosion limit of vacuum interrupter                                      mm0.6
Manual operation moment of forceNm≤200
     
Mechanical characteristics adjustment data    
Rated contact stroke                                      mm13±1
Opening speed                                   m/s1.4±0.2
Three-pole simultaneity                                     ms≤5
Three-pole simultaneity (assembled with isolator)                                    ms≤2
Distance of charged body and relative airmm≥420
Risistance of main circuit                             μΩ≤200