PH meter, digital ph meter, pen type ph meter, PH controller, PH monitor, TDS meter, EC meter, CF meter, ORP controller
PH meter, digital ph meter, pen type ph meter, PH controller, PH monitor, TDS meter, EC meter, CF meter, condutometer, ORP controller, ORP meter
PHscan10/20 Waterproof Pocket pH Tester
Microprocessor-based functions
Two points push-button calibration
Auto-power off after 8 minutes
Hold function
Replaceable electrode
The meter will float into the water
Specifications:
pH Range: 0.0 to 14.0pH
Resolution: 0.1pH
Accuracy: 0.2pH (Model PHscan10)
0.1pH (Model PHscan20)
Calibration Points: 2 points
pH Buffer Options: NIST, pH4.00, pH9.18
Reference Cell type: Replaceable KCl gel filled
Display: LCD
Battery: Three G13-A CNB lithium 1.5V batteries (included)
Battery life: 200 hours continuous
o Operating Temperature: 0 to 60 °C
Dimensions: 180mm Dia.35mm
PH/ORP INDUSTRIAL ON-LINE CONTROLLER
PHC200 pH meter 0-14pH ± 0.01pH
PHC201 pH controller 0-14pH 0-14pH ± 0.01pH
ORPC300 orp meter -1999-+1999mv ± 0.01mv
ORPC301 orp controller -1999-+1999mv 0-1200mv ± 0.01mv
POC231 pH-orp controller pH: 0-14pH
Orp:
-1999+1999mv pH: 0-14pH
Orp: 0-+1200mv pH: ± 0.01pH
Orp: ± 0.01mv
CDC400 conductivity meter 0-199.9ms ± 0.1ms
CDC401 conductivity controller 0-199.9ms 0-100ms ± 0.1ms
KCC500 calcium meter 100-600ppm ± 1ppm
KCC501 calcium controller 100-600ppm 200-500ppm ±
PH-8414 pH/Temp/ORP Meter
High Accuracy Portable pH/Temp/ORP Meter
(noted: ORP function need buy ORP electrode to actualize, standard delivery is without ORP electrode. If with ORP electrode, the model number is ORP-8414)
LCD backlight
Low battery indication
(The red color function is new adding than old model PH-013)
Range | PH:0.00~14.00 mV:0~±1999mV ºC:0~100ºC |
Resolution | PH:0.01PH mV:1mV ºC:0.1ºC |
Accuracy
| PH:±0.01PH mV:±1mV±1digit ºC:±0.4ºC |
Calibration | 1point or 2point |
A T C | 0ºC~95ºC |
Power | 9V battery |
Operating Conditions | 0~60ºC RH≤95% |
Dimensions | 180×82×45mm |
Weight | 290g |
Pocket-size PH Tester
Model | SRP5011 | SRP5021 | SRP5031 | SRP5041 | SRP5051 |
Description | pH Meter | Conductivity Tester | TDS Meter | ORP Meter | Salinity Meter |
Range | 0~14.0pH | 0~100.0μ S/cm 0~1000μ S/cm 0~10.00mS/cm | 0~50.0 ppm 0~500 ppm 0~5.00 ppt | ± 1000mV | 0~5.00ppt |
Resolution | 0.1pH | 0.1/1μ S/cm 0.01mS/cm | 0.1/1ppm 0.01ppt | 1mV | 0.01ppt |
Accuracy | ± 0.2pH | ± 1%FS | ± 1%FS | ± 0.5%FS | ± 1%FS |
Tem Compensation | No | Yes | Yes | No | Yes |
Calibration solution | Yes | Yes | Yes | No | Yes |
Power | AAA batteries*2, 1.5V*2 | ||||
Dimension | 39*25*176 mm |